MPTUTIL Utility
The
mptutil
utility enables you to update the adapter flash memory with the EFI driver and
HBA firmware. New versions of these images are released periodically.
IMPORTANT:
Do not store the files in this package on a SAS device. If you store these files
on a SAS device and the update fails, these files will not be accessible.
To update firmware, follow these steps:
1.
Insert the HPE IPF Offline Diagnostics and Utilities CD in the drive and boot to the EFI Shell.
NOTE:
You can also download the firmware image file and update utility from the Hewlett
Packard Enterprise Support Centre website:
http://www.hpe.com/support/hpesc
.
IMPORTANT:
When you boot the EFI enabled systems, the CD containing the utility must
be in the drive to allow device mapping. The EFI utility and firmware image files are located
in the root directory or in a subdirectory on the CD.
2.
The CD drive displays in the list of mapped devices as
fs0
. To change to this device, enter
fs0:
shell>fs0:\>
fs0:\>
3.
To determine the current version of the firmware, follow these steps.
a.
At the EFI Shell, enter
mptutil
from the directory that contains
mptutil.efi
. The
following example indicates that the EFI Serial Attached SCSI card utility version is
1.01.12.00:
fs0:\EFI\HP\TOOLS\NETWORK> mptutil
MPTUTIL-1.01.12.00
Vendor
Device
Choice
ID
ID
Bus Device
------
------
------
--- ------
0
1000h
0054h
14h
01h
LSI Logic SAS1068 Host Adapter
1
-
Refresh
b.
Press
Enter
.
4.
To update the firmware, use the
mptutil
command.
5.
Reset the controller.
fs0:\> reset
The
mptutil
commands and functions are listed in
and described in the following
sections.
Table 34 mptutil Commands and Functions
Function
Command
Updating HBA RISC firmware on the controller
mptutil -f <firmware_file>
Updating EFI driver on first controller
mptutil -o -g <x86_file> <fcode_file>
Viewing VPD information
mptutil -o -vpd -c 0
Parameters in < > are optional. A space is required between command line options and their parameters.
The following sections describe the
mptutil
commands and functions.
Flashing Firmware on First Controller
To update the HBA RISC firmware on the first controller, follow these steps:
1.
At the
fs0:\>
prompt, enter
mptutil -f <firmware_file> -c 0
.
Core I/O Card Configuration