a.
If both sides of the memory carrier contain the same capacity of memory, install
the next quad in side 0.
b.
If side 0 contains more memory capacity, even though it may have less DIMMs
than side 1, install the next quad in side 1.
c.
If side 1 is full, install the remaining quads in side 0.
shows several examples of proper memory carrier loading order.
IMPORTANT:
The number in parenthesis indicates the order in which the quads are loaded.
Table 25 48-DIMM Memory Carrier Loading Examples
Memory Carrier Side 1
Memory Carrier Side 0
Quad Slot IDs
Quad Number
Example 1
2 GB DIMMs (2)
2 GB DIMMs (1)
0A; 0B; 0C; 0D
0
2 GB DIMMs (4)
2 GB DIMMs (3)
1A; 1B; 1C; 1D
1
1 GB DIMMs (6)
1 GB DIMMs (5)
2A; 2B; 2C; 2D
2
1 GB DIMMs (8)
1 GB DIMMs (7)
3A; 3B; 3C; 3D
3
512 MB (10)
512 MB (9)
4A; 4B; 4C; 4D
4
512 MB (12)
512 MB (11)
5A; 5B; 5C; 5D
5
Example 2
1 GB DIMMs (2)
2 GB DIMMs (1)
0A; 0B; 0C; 0D
0
1 GB DIMMs (3)
1 GB DIMMs (4)
1A; 1B; 1C; 1D
1
512 MB (5)
512 MB (7)
2A; 2B; 2C; 2D
2
512 MB (6)
512 MB (9)
3A; 3B; 3C; 3D
3
512 MB (8)
4A; 4B; 4C; 4D
4
512 MB (10)
5A; 5B; 5C; 5D
5
Example 3
512 MB (2)
2 GB DIMMs (1)
0A; 0B; 0C; 0D
0
512 MB (3)
512 MB (6)
1A; 1B; 1C; 1D
1
512 MB (4)
512 MB (8)
2A; 2B; 2C; 2D
2
512 MB (5)
3A; 3B; 3C; 3D
3
512 MB (7)
4A; 4B; 4C; 4D
4
512 MB (9)
5A; 5B; 5C; 5D
5
Installing Memory
IMPORTANT:
You must pull the AC power plugs on the server every time you modify the
DIMMs. If you do not pull the AC power plugs, the system does not display the correct DIMM
information.
To install memory, follow these steps:
62
Installing the System