Table 19 Environmental Specifications (system processing unit with hard disk) (continued)
Value
Parameter
+44° C (+111.2° F)
Critical over-temperature
1
+48° C (+118.4° F)
Fatal over-temperature shutdown
2
15% to 80% relative (noncondensing)
Operating humidity
90% relative (noncondensing) at + 65° C
Storage humidity
Sound Power Level
3
Acoustic Noise Emission (ISO 7779)
L
WA
=6.8 BA
Typical configuration (disk idle)
4
LWA =6.8 BA
Maximum configuration (disk idle)
5
LWA =6.9 BA
Maximum configuration (disk active)
5
Altitude
0 to 3000 m (10,000 ft.) max
Operating altitude
0 to 4572 m (15,000 ft.) max
Storage altitude
1
If this temperature is reached, iLO enters a TEMPERATURE_HIGH_CRITICAL event in the system log, which might
initiate a graceful OS shutdown, depending on OS configuration (HP-UX
envd(1)
might initiate a reboot or shutdown).
2
If this temperature is reached, iLO enters a TEMPERATURE_HIGH_NON_RECOVERABLE event in the system log
and automatically initiates a system shutdown via interruption of internal DC power (the OS halts immediately).
3
Typical configuration at room temperature (25° C).
4
Single processor, one to two SCSI hard disk drives and less than 8GB of memory.
5
Dual processor, three SCSI hard disk drives and more than 8GB of memory.
Table 20 Physical and Environmental Specifications
Overall System
Dimensions
(W X D X H
Weight
Condition
Airflow, Maximun at
35ºC
1
Airflow, Nominal
Typical
Heat
Release
Pedestal
Rack
Pedestal
Rack
Server
Voltage
200-240
Vac
69.3 cm
(27.3 in)
69.6
cm
Max:
15.5 kg.
(34 lbs.)
150 lbs
(68.04
kg)
max
120-150
lbs.
m³/hr
2
CFM
m³/hr
2
CFM
Watts
Description
x 48.9
cm (19.3
(27.4
in) x 44
154 lbs.
(6909
kg.)
750
441
588
346
433
Minimum
Configuration
in) x
42.2 cm
(16.7 in)
cm
(17.32
in) x
30.58
184 lbs.
(83.5
kg.)
750
441
588
346
1633
Maximum
Configuration
cm
(12.04
in)
750
441
588
346
998
Typical
Configuration
(1x) Itanium 1.4G/12M or 1.6G/18M or 1.6G/24M
CPUs, (4x) 4GB DDRII DIMM memory, (0x) SAS
Minimum
Configuration
Air Flow Diagram Cooling Scheme (F
- R)
ASHRAE
Class 1
Hard Drives, (0x) PCI/PCI-X/PCIe added to
public I/O cards.
Environmental Specifications
41