Antenna
Calibration
8.
Move
the
positioner
so
the
antenna
is
somewhere
near
its
boresight
position
(a
rough
approximation
is
ne).
9.
Move
the
positioner
until
the
at
line
reaches
maximum
amplitude
(or
minimum
amplitude
if
your
antenna
has
a
null
at
boresight).
It
is
helpful
to
watch
the
marker
value
readout
(in
the
upper-left
portion
of
the
display).
This
digital
readout
of
the
amplitude
makes
it
easy
to
observe
small
(0.1
dB)
changes
.
10.
Boresighting
is
usually
interactive
between
axes
,
so
repeat
steps
5,
6,
and
7
for
each
axis
until
true
boresight
is
found.
Choosing
Calibration
Stimulus
Settings
1.
P
erform
step
a
or
b
below
,
depending
on
if
you
want
to
calibrate
at
one
or
more
frequency
points
.
a.
If
you
only
want
to
calibrate
at
a
single
frequency
press
STIMULUS
4
MENU
5
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
SINGLE
POINT
.
Press
4
CENTER
5
followed
by
the
desired
frequency
,
proceed
to
Antenna
Calibration
Steps,
below
.
b.
T
o
calibrate
over
a
range
of
frequencies
,
you
must
choose
a
sweep
mode
.
Any
mode
will
work
but
the
Frequency
List
mode
is
strongly
recommended.
The
Frequency
List
NNNNNNNNNNNNNNNNNNNNNNNNNNNNN
STEP
SIZE
function
allows
you
to
enter
a
known
increment
frequency.
This
is
why
the
Frequency
List
mode
is
better
when
performing
a
calibration.
Ramp
and
step
sweep
modes
only
allow
you
to
choose
a
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
NUMBER
of
POINTS
,
and
the
receiver
chooses
the
increment
frequency
.
This
limits
exibility
in
the
calibration
and
often
results
in
inconvenient
increment
values
(like
17.67
MHz).
STEP
SIZE
allows
you
to
choose
a
step
size
that
is
convenient.
Note
Ramp
Sweep
mode
is
not
always
usable
,
depending
on
how
your
system
is
congured.
Ramp
Sweep
mode
will
not
function
is
systems
that
use
an
LO
source
.
In
addition,
Ramp
Sweep
requires
two
BNC
connections
between
the
receiver
and
the
RF
source
.
Sometimes
wide
frequency
ranges
require
you
to
use
two
or
more
standard
gain
antennas
to
cover
the
whole
frequency
range
.
If
this
is
the
case
,
enter
the
entire
frequency
range
during
the
procedure
below
.
T
o
use
Frequency
List
mode
,
as
recommended,
perform
the
following
sub
steps:
i.
Press
STIMULUS
4
MENU
5
NNNNNNNNNNNNNN
MORE
NNNNNNNNNNNNNNNNNNNNNNNNNNNNN
EDIT
LIST
.
ii.
Press
NNNNNNNNNNNNNN
EDIT
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
SEGMENT:
START
and
enter
the
desired
start
frequency
(for
example
,
8.2
GHZ).
iii.
Press
NNNNNNNNNNNNNN
STOP
and
enter
the
desired
stop
frequency
(for
example
,
12.4
GHz).
iv
.
Press
N
NNNNNNNNNNNNNNNNNNNNNNNNNNNN
STEP
SIZE
and
enter
the
desired
frequency
increment
value
.
Assume
for
a
moment
that
your
standard
gain
antenna
has
documented
gain
values
every
50
MHz.
Y
ou
can
choose
smaller
increments
(for
example
,
25
MHz),
and
the
receiver
will
interpolate
between
known
gain
points
.
(Straight-line
interpolation
is
performed.)
v
.
Press
NNNNNNNNNNNNNN
DONE
.
The
receiver
will
display
the
number
of
points
it
will
use
in
the
measurement,
based
on
the
selected
step
size
.
vi.
Press
NNNNNNNNNNNNNN
DONE
again.
vii.
Press
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
FREQUENCY
LIST
to
select
Frequency
List
mode
.
5-12
Menus
Block
Содержание 8530A
Страница 9: ......
Страница 31: ......
Страница 34: ...General Information Figure 1 2 Antenna Measurement Setup Using an HP 85310A GeneralInformation 1 3 ...
Страница 51: ......
Страница 65: ......
Страница 81: ......
Страница 83: ......
Страница 84: ...5 Menus Block Chapter Contents Calibration Domain Display Markers MenusBlock 5 1 ...
Страница 85: ...5 2 Menus Block ...
Страница 90: ...Calibration Requirements Figure 5 1 Cal and Cal Type Menus MenusBlock 5 7 ...
Страница 93: ...Antenna Calibration 5 10 MenusBlock ...
Страница 167: ......
Страница 195: ......
Страница 201: ......
Страница 209: ......
Страница 249: ......
Страница 281: ......
Страница 411: ......
Страница 419: ...Glossary Glossary 8 ...