Controls
that
Aect
the
Receiver
W
arning
Beeper
The
NNNNNNNNNNNNNNNNNNNNNNNNNNNNN
BEEPER
ON
/
NNNNNNNNNNN
OFF
softkeys
control
whether
you
hear
a
\beep"
whenever
a
warning
message
is
displayed.
The
BEEPER
ON
position
is
the
factory
default.
IF
Calibration
and
Correction
IF
calibration/correction
is
an
automatic
calibration
feature
that
reduces
IF
gain
and
quadrature
errors
in
each
of
the
four
input
channels
(a1,
a2,
b1
and
b2).
This
process
is
composed
of
two
features:
IF
Calibration
IF
calibration
measures
a
crystal
reference
signal
and
determines
gain
a
quadrature
errors
for
each
input
channel.
A
series
of
error-correction
coecients
are
calculated.
The
receiver
rmware
determines
how
often
IF
calibrations
should
be
performed.
When
the
receiver
is
warming
up
,
it
performs
IF
calibrations
often.
When
the
receiver
is
fully
warmed
up
,
it
performs
IF
calibrations
less
often.
Refer
to
Figure
2-1 .
T
o
perform
an
IF
calibration,
the
receiver
measures
a
100
kHz
reference
signal
(from
a
built-in
crystal
oscillator)
with
the
T
est
and
Reference
Synchronous
Detectors
.
Then,
IF
calibration
calculates
gain
and
quadrature
errors
for
each
input
channel.
The
receiver
inhibits
periodic
IF
calibrations
during
F
ast
CW
modes
.
The
user
can
also
turn
periodic
IF
calibrations
OFF
.
Y
ou
can
also
force
an
IF
calibration
to
be
performed.
Refer
to
the
\IF
Calibration
Controls
,"
below
,
for
instructions
.
IF
Correction
IF
Correction
subtracts
IF
calibration
error
coecients
from
the
measurement
data.
IF
correction
is
always
ON.
IF
correction
occurs
before
any
other
data
processing,
before
data
reaches
the
Raw
Data
Arrays
.
IF
Calibration
Controls
Press
4
SYSTEM
5
N
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
IF
CORRECTION
to
access
the
IF
Calibration
controls
,
which
are
described
below:
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
RESET
IF
CORRECTION
This
softkey
initiates
an
IF
gain
calibration
before
starting
the
next
group
of
sweeps
.
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
IF
CORRECT:
AUTO
This
is
the
factory-default
setting.
When
A
UTO
is
selected,
the
receiver
automatically
performs
IF
calibrations
at
periodic
intervals
.
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
IF
CORRECT:
MANUAL
This
setting
stops
IF
calibrations
from
occurring
automatically
.
Y
ou
can
manually
perform
an
IF
calibration
by
pressing:
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
RESET
IF
CORRECTION
Even
if
Manual
mode
is
selected,
the
receiver
still
modies
measurement
data
with
the
most-recent
IF
calibration
coecients
.
Using
System
Functions
17-5
Содержание 8530A
Страница 9: ......
Страница 31: ......
Страница 34: ...General Information Figure 1 2 Antenna Measurement Setup Using an HP 85310A GeneralInformation 1 3 ...
Страница 51: ......
Страница 65: ......
Страница 81: ......
Страница 83: ......
Страница 84: ...5 Menus Block Chapter Contents Calibration Domain Display Markers MenusBlock 5 1 ...
Страница 85: ...5 2 Menus Block ...
Страница 90: ...Calibration Requirements Figure 5 1 Cal and Cal Type Menus MenusBlock 5 7 ...
Страница 93: ...Antenna Calibration 5 10 MenusBlock ...
Страница 167: ......
Страница 195: ......
Страница 201: ......
Страница 209: ......
Страница 249: ......
Страница 281: ......
Страница 411: ......
Страница 419: ...Glossary Glossary 8 ...
Страница 439: ......