Programming
Examples
Example
24:
Input
Floating
P
oint
or
ASCII
Trace
Data
This
example
writes
trace
data
to
the
receiver
in
either
Floating
P
oint
(FORM
3)
or
ASCII
(FORM
4)
formats
.
The
data
array
is
continuously
re-written
to
the
display
with
an
oset
added
each
time
.
Note
the
dierence
in
speed
between
the
two
data
formats
.
Example
25:
T
able
Delay
Operations
This
example
demonstrates
how
to
input,
output
and
apply
T
able
Delay
.
The
Delay
T
able
in
also
stored
and
loaded
using
the
receiver
internal
disc
.
Example
26:
F
AST
(CW
,AD
,D)
Data
A
cquisition
F
ast
CW
setup
and
operation
is
demonstrated
using
an
external
trigger
source
.
Once
the
data
is
collected,
it
is
converted
from
FORM
1
to
real,
imaginary
data
pairs
.
See
Chapter
8,
A
utomatic
Measurements
,
in
the
HP
8530A
Microwave
R
eceiver
User's
Guide
for
more
information
on
the
fast
CW
mode
.
Example
27:
F
ast
IF
Multiplexing
Operation
This
example
has
been
written
as
a
stand-alone
program
which
sets-up
a
fast
IF
multiplexing
mode
measurement
of
two
parameters
(using
FASMUXMODE
2; )
and
then
measures
and
transfers
the
data
to
the
controller
.
The
measurement
and
transfer
will
continue
until
the
user
exits
the
program
or
until
the
100k
buer
overows
.
See
Chapter
8,
A
utomatic
Measurements
,
in
the
HP
8530A
Microwave
R
eceiver
User's
Guide
for
more
information
on
the
fast
CW
mode
.
General
HP-IB
Programming
After
the
HP-IB
REMOTE
command
is
issued,
addressing
the
receiver
using
an
appropriate
OUTPUT
statement
causes
the
receiver
to
enter
the
Remote
mode
in
which
the
front
panel
hardkeys
and
softkeys
are
locked
out.
The
only
key
that
is
no
locked
out
is
the
4
LOCAL
5
key
.
After
the
initial
OUTPUT
statement,
either
ENTER
or
OUTPUT
statements
are
accepted.
Press
the
4
LOCAL
5
key
to
restore
front
panel
control
functions
until
the
next
OUTPUT
command
is
received.
Program
the
Local
Lockout
command,
LLO ,
to
lock
out
the
front
panel
completely
,
even
the
4
LOCAL
5
key
.
Issue
the
HP-IB
LOCAL
command
to
cancel
Local
Lockout,
then
issue
a
REN
command
to
return
the
receiver
to
remote
command.
If
the
receiver
is
already
addressed
as
a
listener
,
a
GTL
716
(LOCAL
716)
sets
the
receiver
system
to
the
normal
manual
mode
without
changing
the
current
instrument
state
.
All
HP-IB
Universal
and
A
ddressed
Commands
and
the
receiver
system
response
to
the
commands
are
listed
below
.
computer-specic
and
language
considerations
are
discussed
in
the
\Example
Program
Listings"
later
in
this
chapter
.
18-32
HP-IB
Programming
Содержание 8530A
Страница 9: ......
Страница 31: ......
Страница 34: ...General Information Figure 1 2 Antenna Measurement Setup Using an HP 85310A GeneralInformation 1 3 ...
Страница 51: ......
Страница 65: ......
Страница 81: ......
Страница 83: ......
Страница 84: ...5 Menus Block Chapter Contents Calibration Domain Display Markers MenusBlock 5 1 ...
Страница 85: ...5 2 Menus Block ...
Страница 90: ...Calibration Requirements Figure 5 1 Cal and Cal Type Menus MenusBlock 5 7 ...
Страница 93: ...Antenna Calibration 5 10 MenusBlock ...
Страница 167: ......
Страница 195: ......
Страница 201: ......
Страница 209: ......
Страница 249: ......
Страница 281: ......
Страница 411: ......
Страница 419: ...Glossary Glossary 8 ...
Страница 439: ......