
HP
8530A
F
eatures
Calibration
Antenna
calibration
provides
accurate
gain
and
frequency
response
measurements
by
calibrating
your
range
against
a
standard
gain
antenna.
Also
,
the
isolation
calibration
feature
reduces
measurement
errors
caused
by
signal
crosstalk.
RCS
Response
and
Isolation
calibration
is
also
supplied.
This
calibration
reduces
range
errors
using
a
calibration
sphere
of
known
radar
cross
section.
The
response
portion
of
the
calibration
measures
the
reections
of
the
calibration
sphere
.
The
isolation
portion
measures
the
empty
antenna
chamber
to
characterize
and
compensate
for
clutter
.
F
our
reection
standards
are
supported.
A
\network
analyzer"
calibration
is
also
provided.
This
calibration
is
used
if
you
want
to
make
network
analyzer-type
measurements
.
F
or
example
,
assume
you
want
to
measure
the
impedance
of
an
antenna
input
(or
output).
Y
ou
would
perform
the
network
analyzer
calibration
so
you
could
make
very
accurate
measurements
.
In
this
example
a
directional
coupler
is
required
to
measure
the
reected
signals
.
F
our
Measurement
Inputs
The
receiver
has
four
inputs
for
receiving
signals
(a1,
a2,
b1
and
b2).
Y
ou
must
connect
a
reference
signal
to
a1
or
a2.
Then,
any
other
inputs
can
be
used
as
test
signal
inputs
.
F
or
example
,
assume
you
connect
the
reference
signal
into
a1.
Y
ou
could
then
use
a2,
b1,
and
b2
to
measure
test
signals
.
The
\P
ARAM"
keys
,
described
below
,
select
which
inputs
to
ratio
for
your
measurement.
Selectable
Input
Ratios
4
P
ARAM
1
5 ,
4
P
ARAM
2
5 ,
4
P
ARAM
3
5 ,
and
4
P
ARAM
4
5 ,
select
a
specic
pair
of
inputs
to
ratio
and
measure
.
(\P
ARAM"
is
short
for
\parameter
.")
F
or
example
,
4
P
ARAM
1
5
mathematically
divides
(ratios)
input
b1
data
by
a1
data.
Y
ou
can
redene
the
P
ARAM
keys
so
they
ratio
any
two
inputs
you
desire
.
Y
ou
can
also
measure
a
single
input
without
ratioing.
By
default,
the
four
parameters
ratio
the
following
inputs:
4
P
ARAM
1
5
b1/a1
4
P
ARAM
2
5
b2/a1
4
P
ARAM
3
5
a2/a1
4
P
ARAM
4
5
b1/a1
Notice
that
the
default
ratio
for
P
aram
1
and
P
aram
4
are
the
same
.
Y
ou
can
redene
the
ratios
for
P
aram
1,
2,
3
or
4
using
the
softkeys
under
P
ARAMETER
4
MENU
5
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
REDEFINE
PARAMETER
.
Flexible
Triggering
The
HP
8530A
provides
three
ways
of
triggering
measurements:
Free
Run
When
you
select
\Free
Run"
the
receiver
does
not
require
any
triggering.
This
is
useful
when
making
frequency
measurements
.
External
Triggering
Allows
you
to
trigger
measurements
using
a
TTL
increment
signal
produced
by
a
positioner
controller
.
This
allows
the
receiver
to
take
data
when
the
positioner
is
aligned
with
each
measurement
angle
.
HP-IB
Triggering
Allows
a
computer
to
trigger
a
measurement
by
issuing
a
GET
command
over
the
HP-IB
bus
.
1-6
General
Information
Содержание 8530A
Страница 9: ......
Страница 31: ......
Страница 34: ...General Information Figure 1 2 Antenna Measurement Setup Using an HP 85310A GeneralInformation 1 3 ...
Страница 51: ......
Страница 65: ......
Страница 81: ......
Страница 83: ......
Страница 84: ...5 Menus Block Chapter Contents Calibration Domain Display Markers MenusBlock 5 1 ...
Страница 85: ...5 2 Menus Block ...
Страница 90: ...Calibration Requirements Figure 5 1 Cal and Cal Type Menus MenusBlock 5 7 ...
Страница 93: ...Antenna Calibration 5 10 MenusBlock ...
Страница 167: ......
Страница 195: ......
Страница 201: ......
Страница 209: ......
Страница 249: ......
Страница 281: ......
Страница 411: ......
Страница 419: ...Glossary Glossary 8 ...
Страница 439: ......