Hardware
Problems
3.
If
you
are
using
the
HP
85309A
frequency
converter
,
and
the
problem
is
with
one
of
the
sources:
check
multiple
source
settings
on
the
receiver
.
Refer
to
the
HP
85310A
documentation
for
details
.
Also
refer
to
the
description
of
Multiple
Source
Mode
operation
in
Chapter
17,
Using
System
Functions
.
4.
Check
HP-IB
extenders
by
performing
these
steps:
a.
Make
sure
the
extenders
are
set
to
SLOW
mode
.
NORMAL
mode
can
cause
errors
.
b.
Make
sure
the
extenders
are
plugged
in,
and
that
their
switches
are
set
properly
.
c.
Check
the
extender
cables
for
breaks
or
damage
.
5.
Disconnect
the
extender
from
the
receiver
.
Turn
the
receiver
OFF
,
then
ON.
W
ait
20
seconds
.
Reconnect
the
extender
.
6.
If
all
of
the
above
is
correct:
a.
Suspect
a
failure
in
one
of
the
extenders
.
Connect
the
source
directly
to
the
receiver
System
Bus
and
check
operation.
b.
Suspect
a
bad
HP-IB
cable
,
or
a
bad
extender
coaxial
cable
.
c.
After
checking
all
other
items
,
suspect
a
failure
in
one
of
the
instrument's
HP-IB
circuits
.
If
the
instrument
does
not
operate
manually
Suspect
a
failure
within
the
instrument
itself.
HP
85309A
(LO/IF
Unit)
Problems
This
section
only
applies
to
HP
85309A
frequency
converters
.
LO/IF
Unit
Does
Not
Turn
ON
If
the
DETECTOR
V
OL
T
A
GE
display
on
the
front
panel
does
not
light
up
when
the
unit
is
turned
on,
check
the
following:
1.
Make
sure
the
instrument
is
plugged
into
an
operating
A
C
power
outlet.
2.
Check
the
instrument's
line
voltage
selector
.
Is
it
set
to
your
A
C
power
voltage?
3.
Check
the
HP
85309A's
fuse
.
4.
Check
the
power
supply
as
explained
in
the
service
chapter
of
the
HP
85301B
or
HP
85310A
operating
and
service
manual.
The
LO
PO
WER
OUT
OF
RANGE
Light
is
ON
This
can
be
caused
by
the
following:
The
LO
source
is
not
set
to
output
enough
power
,
increase
power
output
(if
possible)
to
+13
dBm.
Make
sure
your
LO
source
can
output
enough
power
at
the
highest
LO
frequency
.
The
LO
source's
RF
OUTPUT
is
not
connected
to
the
HP
85309A,
or
if
the
LO
source
is
turned
o.
This
can
also
happen
if
the
LO
source
is
on,
but
its
RF
output
is
turned
o.
The
LO
source
cannot
supply
the
requested
amount
of
power
in
the
measurement
frequency
range
.
Make
sure
your
LO
source
is
specied
to
produce
+10
dBm
in
the
desired
frequency
range
.
If
the
LO
cannot
produce
enough
power
at
high
frequencies
,
the
LO
POWER
OUT
OF
20-14
In
Case
of
Diculty
Содержание 8530A
Страница 9: ......
Страница 31: ......
Страница 34: ...General Information Figure 1 2 Antenna Measurement Setup Using an HP 85310A GeneralInformation 1 3 ...
Страница 51: ......
Страница 65: ......
Страница 81: ......
Страница 83: ......
Страница 84: ...5 Menus Block Chapter Contents Calibration Domain Display Markers MenusBlock 5 1 ...
Страница 85: ...5 2 Menus Block ...
Страница 90: ...Calibration Requirements Figure 5 1 Cal and Cal Type Menus MenusBlock 5 7 ...
Страница 93: ...Antenna Calibration 5 10 MenusBlock ...
Страница 167: ......
Страница 195: ......
Страница 201: ......
Страница 209: ......
Страница 249: ......
Страница 281: ......
Страница 411: ......
Страница 419: ...Glossary Glossary 8 ...
Страница 439: ......