Entry
Block
Changing
V
alues
Using
the
Numeric
K
eypad
T
o
change
a
value
using
the
numeric
keypad:
1.
Select
the
function
(start
angle
,
frequency
,
or
any
other
function
that
requires
a
value).
This
function
becomes
the
\active
function."
Notice
that
the
function
now
appears
in
the
\active
function
area"
of
the
display
.
2.
Enter
the
new
value
using
numeric
keys
,
decimal
point,
and
a
terminator
key
.
T
o
change
the
sign
of
the
entry
,
press
4
+/0
5 .
If
you
make
a
mistake
,
press
the
4
BACKSP
A
CE
5
key
.
(If
you
have
already
pressed
a
terminator
key
,
you
must
re-enter
the
entire
value).
3.
T
erminate
the
entry
with
the
appropriate
units
.
T
able
10-1.
Numeric
V
alue
T
erminator
K
ey
Usage
K
ey
Name
Angle
Frequency
P
ower
P
ower
Slope
Time
Distance
G/n
0
GHz
0
0
ns
nm
M/
0
MHz
0
0
s
m
k/m
milli
degrees
kHz
0
0
ms
mm
x1
1
degrees
Hz
dBm
dB/Ghz
s
m
1
4
x1
5
always
represents
single
units
.
Other
K
eys
in
the
Entry
Block
4
ENTRY
OFF
5
Removes
old
error
messages
or
active
function
text
from
the
screen.
\A
ctive
function
text"
are
messages
like
START
090
that
appear
when
you
changed
the
value
of
a
function.
4
PRIOR
MENU
5
This
key
takes
you
to
the
previous
softkey
menu.
4
=MARKER
5
This
key
can
be
useful
when
you
are
using
markers
.
The
easiest
way
to
explain
what
4
=MARKER
5
does
is
by
example
.
Assume
you
are
making
a
frequency
response
measurement,
and
the
last
marker
you
moved
(the
active
marker)
is
sitting
at
11
GHz.
Now
assume
you
want
to
change
the
center
frequency
to
11
GHz.
All
you
need
to
do
is
press
4
CENTER
5
4
=MARKER
5 .
The
marker
position
(11
GHz)
will
become
the
center
frequency
.
Another
way
to
use
4
=MARKER
5
is
to
transfer
the
marker
value
to
another
function.
As
an
example
,
assume
you
want
to
set
the
display
reference
line
to
the
value
of
the
active
marker
(for
example
,
assume
the
marker
value
is
013.2
dB).
Press
4
REF
V
ALUE
5
4
=MARKER
5 ,
and
the
display
reference
line
will
change
to
the
value
of
the
active
marker
.
10-2
Entry
Block
Controls
Содержание 8530A
Страница 9: ......
Страница 31: ......
Страница 34: ...General Information Figure 1 2 Antenna Measurement Setup Using an HP 85310A GeneralInformation 1 3 ...
Страница 51: ......
Страница 65: ......
Страница 81: ......
Страница 83: ......
Страница 84: ...5 Menus Block Chapter Contents Calibration Domain Display Markers MenusBlock 5 1 ...
Страница 85: ...5 2 Menus Block ...
Страница 90: ...Calibration Requirements Figure 5 1 Cal and Cal Type Menus MenusBlock 5 7 ...
Страница 93: ...Antenna Calibration 5 10 MenusBlock ...
Страница 167: ......
Страница 195: ......
Страница 201: ......
Страница 209: ......
Страница 249: ......
Страница 281: ......
Страница 411: ......
Страница 419: ...Glossary Glossary 8 ...
Страница 439: ......