Modifying
a
Network
Analyzer
Cal
Set
After
F
actory
Preset,
the
receiver
automatically
selects
a
faster
sweep
for
51
points
than
for
801
points
.
If
the
receiver's
sweep
time
is
changed
after
calibration,
a
caution
is
displayed
in
order
to
alert
the
user
to
examine
the
resulting
data
carefully
.
The
dynamics
of
the
measurement
process
change
and
the
accuracy
of
the
data
may
be
aected.
F
or
best
results
press
STIMULUS
4
MENU
5
then
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
SWEEP
TIME
and
set
the
sweep
time
to
200
ms
(milliseconds)
prior
to
measurement
calibration.
Now
the
sweep
time
will
remain
constant
regardless
of
the
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
NUMBER
OF
POINTS
selection.
Dening
a
Frequency
Subset
After
calibration
in
either
ramp
,
step
,
or
frequency
list
sweep
mode
,
a
subset
of
the
current
frequency
range
can
be
selected
by
choosing
new
ST
ART/STOP
or
CENTER/SP
AN
frequencies
and
a
new
calibration
set.
This
provides
a
very
useful
\frequency
zoom"
function
by
allowing
the
user
to
select
any
subset
of
the
current
frequency
sweep
.
This
results
in
faster
sweeps
because
fewer
points
are
measured.
The
frequency
subset
menu
is
shown
in
Figure
5-13.
Figure
5-13.
Modify
Cal
Set,
Frequency
Subset
Menu
Create
and
Save
the
Frequency
Subset
T
o
dene
a
frequency
subset:
1.
Turn
correction
ON.
2.
Press:
4
CAL
5
NNNNNNNNNNNNNN
MORE
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
MODIFY
CAL
SET
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
FREQUENCY
SUBSET
As
shown
in
Figure
5-14,
markers
appear
on
the
trace
to
show
you
the
current
ST
ART/STOP
or
CENTER/SP
AN
of
the
frequency
subset.
3.
P
osition
these
markers
by
pressing
the
N
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
SUBSET:
START
,
N
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
SUBSET:
STOP
,
N
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
SUBSET:
CENTER
or
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
SUBSET:
SPAN
softkeys
and
using
the
knob
,
step
keys
,
or
numeric
entry
keypad.
4.
Now
press
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
CREATE
&
SAVE
,
then
select
a
new
calibration
set.
If
you
choose
a
register
that
holds
an
existing
cal
set,
the
new
cal
set
will
overwrite
the
one
currently
in
that
register
.
Menus
Block
5-43
Содержание 8530A
Страница 9: ......
Страница 31: ......
Страница 34: ...General Information Figure 1 2 Antenna Measurement Setup Using an HP 85310A GeneralInformation 1 3 ...
Страница 51: ......
Страница 65: ......
Страница 81: ......
Страница 83: ......
Страница 84: ...5 Menus Block Chapter Contents Calibration Domain Display Markers MenusBlock 5 1 ...
Страница 85: ...5 2 Menus Block ...
Страница 90: ...Calibration Requirements Figure 5 1 Cal and Cal Type Menus MenusBlock 5 7 ...
Страница 93: ...Antenna Calibration 5 10 MenusBlock ...
Страница 167: ......
Страница 195: ......
Страница 201: ......
Страница 209: ......
Страница 249: ......
Страница 281: ......
Страница 411: ......
Страница 419: ...Glossary Glossary 8 ...
Страница 439: ......