Front
P
anel
F
eatures
Other
K
eys
in
the
Entry
Block
4
ENTRY
OFF
5
Removes
old
error
messages
or
active
function
text
from
the
screen.
\A
ctive
function
text"
is
a
message
such
as:
START
090
that
appears
when
you
change
the
value
of
a
function.
4
PRIOR
MENU
5
This
key
takes
you
to
the
previous
softkey
menu.
4
=MARKER
5
This
key
can
be
useful
when
you
are
using
markers
.
The
easiest
way
to
explain
what
4
=MARKER
5
does
is
by
example
.
Assume
you
are
making
a
frequency
response
measurement,
and
the
last
marker
you
moved
(the
active
marker)
is
sitting
at
11
GHz.
Now
assume
you
want
to
change
the
center
frequency
to
11
GHz.
All
you
need
to
do
is
press
4
CENTER
5
4
=MARKER
5 .
The
marker
position
(11
GHz)
will
become
the
center
frequency
.
Another
way
to
use
4
=MARKER
5
is
to
transfer
the
marker
value
to
another
function.
As
an
example
,
assume
you
want
to
set
the
display
reference
line
to
the
value
of
the
active
marker
(for
example
,
assume
the
marker
value
is
013.2
dB).
Press
4
REF
V
ALUE
5
4
=MARKER
5 ,
and
the
display
reference
line
will
change
to
the
value
of
the
active
marker
.
MENUS
Block
The
four
keys
under
MENUS
are
4
CAL
5 ,
4
DOMAIN
5 ,
4
DISPLA
Y
5 ,
and
4
MARKER
5 :
CAL
Softkeys
under
4
CAL
5
allow
you
to
perform:
Antenna
calibration
Radar
cross
section
(RCS)
calibration
1-P
ort
network
analyzer
calibration
DOMAIN
The
HP
8530
has
three
modes
of
operation,
called
domains:
Frequency
Domain
Angle
Domain
Optional
Time
Domain
DISPLA
Y
Softkeys
under
4
DISPLA
Y
5 :
Display
one
,
two
,
three
,
or
four
parameter
measurements
.
Save
the
data
trace
to
temporary
storage
memory
.
Display
memory
traces
.
P
erform
trace
math
functions
on
memory
traces
.
Allow
you
to
change
display
intensity
or
colors
.
Allow
you
to
choose
video
settings
for
an
external
monitor
.
MARKER
Softkeys
under
4
MARKER
5
allow
you
to
activate
up
to
ve
markers
.
Each
marker
shows
amplitude
or
phase
values
for
a
desired
point
on
the
measurement
trace
.
Marker
Functions
are:
Basic
markers
on
the
display
trace
.
Delta
marker
mode
.
Front
and
Rear
Panel
3-9
Содержание 8530A
Страница 9: ......
Страница 31: ......
Страница 34: ...General Information Figure 1 2 Antenna Measurement Setup Using an HP 85310A GeneralInformation 1 3 ...
Страница 51: ......
Страница 65: ......
Страница 81: ......
Страница 83: ......
Страница 84: ...5 Menus Block Chapter Contents Calibration Domain Display Markers MenusBlock 5 1 ...
Страница 85: ...5 2 Menus Block ...
Страница 90: ...Calibration Requirements Figure 5 1 Cal and Cal Type Menus MenusBlock 5 7 ...
Страница 93: ...Antenna Calibration 5 10 MenusBlock ...
Страница 167: ......
Страница 195: ......
Страница 201: ......
Страница 209: ......
Страница 249: ......
Страница 281: ......
Страница 411: ......
Страница 419: ...Glossary Glossary 8 ...
Страница 439: ......