Modifying
Network
Analyzer
Cal
Kit
Denitions
C
total
=
C
0
+
C
1
*F
+
C
2
*F
2
+
C
3
*F
3
Where
C
0
is
the
DC
capacitance
,
C
1
*F
is
the
capacitance
times
frequency
,
C
2
*F
2
is
the
capacitance
times
frequency
squared,
and
C
3
*F
3
is
the
capacitance
times
frequency
cubed.
The
shielded
open
circuits
in
the
3.5
mm
calibration
kit
use
a
center
pin
extender
,
so
the
models
for
these
devices
also
include
a
linear
phase
shift
component
to
account
for
the
oset
from
the
reference
plane
.
Specications
,
Modifying
a
Cal
Kit
The
specications
contained
on
the
calibration
kit
data
le
are
nominal
values
based
on
typical
expected
responses
of
the
standards
.
If
you
wish
to
substitute
your
own
standards
,
or
change
the
models
for
the
standards
supplied
in
the
calibration
kit,
you
may
use
the
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
MODIFY
CAL
KIT
sequence
.
Common
Problems
Common
calibration
problems
which
can
be
traced
to
standards
are:
Non-repeatable
contact
due
to
wear
,
dirt,
grease
,
or
other
contaminants
on
the
contacting
surfaces
or
other
accessible
parts
of
the
standard.
Assure
that
the
standard
is
properly
cleaned.
Make
sure
the
connector
is
dry
.
Connector
damage
due
to
connecting
the
standard
to
a
connector
with
mechanical
defects
or
out-of-spec
tolerances
.
Use
the
connector
gage
on
both
the
test
port
and
the
standard
prior
to
measurement
calibration.
P
oor
contact
due
to
improper
alignment
or
torquing
practice
.
Use
the
correct
connection
technique
and
the
proper
torque
wrench
for
each
connection.
Using
cal
standards
whose
response
does
not
match
the
constants
in
HP
8530
Cal
Kit
memory
.
Load
the
proper
cal
kit
data
le
for
the
cal
kit
you
are
using.
V
erifying
Calibration
Data
Immediately
following
calibration,
and
at
intervals
during
the
measurement
process
,
it
is
recommended
that
you
measure
a
standard
device
with
known
responses
.
This
is
to
verify
that
the
system
characteristics
have
not
changed
thus
making
the
current
calibration
error
coecients
invalid.
Measuring
a
device
from
the
calibration
kit
used
for
measurement
calibration
will
allow
you
to
determine
that
the
system
is
making
repeatable
measurements
.
The
measured
response
of
a
calibration
standard
will
be
exactly
the
modeled
response
if
the
connection
is
repeatable
.
T
o
determine
measurement
accuracy
,
however
,
it
is
necessary
to
measure
an
independent
standard
with
known
responses
,
such
as
the
attenuators
or
air
lines
in
the
HP
8510
verication
kit,
or
a
standard
you
produce
that
is
representative
of
the
devices
you
are
testing.
If
standards-quality
data
for
the
device
is
available
,
it
can
be
compared
with
your
measurement
results
to
determine
accuracy
.
If
the
data
is
outside
acceptable
limits
and
good
technique
was
used
during
the
calibration,
then
the
system
characteristics
have
changed,
thus
making
the
current
calibration
error
coecients
invalid.
Standards-quality
measurement
data
is
supplied
with
the
HP
verication
devices
.
Menus
Block
5-39
Содержание 8530A
Страница 9: ......
Страница 31: ......
Страница 34: ...General Information Figure 1 2 Antenna Measurement Setup Using an HP 85310A GeneralInformation 1 3 ...
Страница 51: ......
Страница 65: ......
Страница 81: ......
Страница 83: ......
Страница 84: ...5 Menus Block Chapter Contents Calibration Domain Display Markers MenusBlock 5 1 ...
Страница 85: ...5 2 Menus Block ...
Страница 90: ...Calibration Requirements Figure 5 1 Cal and Cal Type Menus MenusBlock 5 7 ...
Страница 93: ...Antenna Calibration 5 10 MenusBlock ...
Страница 167: ......
Страница 195: ......
Страница 201: ......
Страница 209: ......
Страница 249: ......
Страница 281: ......
Страница 411: ......
Страница 419: ...Glossary Glossary 8 ...
Страница 439: ......