2–68
edge switch 2/24 service manual
Diagnostics
12
A link incident may have occurred, but the LIN alerts option is not enabled for the port
and the attention indicator does not appear.
At the Hardware View, click Logs and select Link Incident Log. The Link Incident
Log displays. If a link incident occurred, the affected port number is listed with one of
the following messages.
Link interface incident - implicit incident.
Link interface incident - bit-error threshold exceeded.
Link failure - loss of signal or loss of synchronization.
Link failure - not-operational primitive sequence (NOS)
received.
Link failure - primitive sequence timeout.
Link failure - invalid primitive sequence received for the
current link state.
Did one of the listed messages appear in the Link Incident Log?
YES
NO
↓
The switch appears operational. Exit MAP.
Go to
step 25
.
Link Incident
Off
Off
Go to
step 25
.
Segmented
E_Port
On
Off
Go to
MAP 0700
.
Table 2–11: Port Operational and LED States (Continued)
Operational
State
Green
LED
Amber
LED
Action