edge switch 2/24 service manual
B–27
Event Codes
CTP Card Events (400 through 499)
Event Code: 400
Message:
Power-up diagnostics failure.
Severity:
Major.
Explanation:
Power-on self tests (POSTs) detected a faulty field-replaceable unit (FRU) as indicated
by the event data.
Action:
If a CTP card failure is indicated, replace the switch. If a fan or power supply failure is
indicated, replace the power supply assembly. Perform the data collection procedure
and return the Zip disk to Hewlett-Packard support personnel.
Event Data:
Byte 0 = FRU code as follows: 02 = CTP card, 05 = cooling fan, 06 = power supply
assembly.
Byte 1 = FRU slot number.
Distribution:
Switch
HAFM Server
Host
EWS
Event
Log
System
Error
LED
Event
Log
Call
Home
Sense
Info
Link
Incident
✔
✔
✔
✔
✔
✔
Event Code: 410
Message:
Switch reset.
Severity:
Informational.
Explanation:
The switch reset due to system power-up, IML, or manual reset. A software reset can
occur automatically after a firmware fault (event code 411), or be user-initiated. Event
data indicates the type of reset.
Action:
No action required.
Event Data:
Byte 0 = reset type as follows: 00 = power-on, 02 = IML, 04 = reset.
Distribution:
Switch
HAFM Server
Host
EWS
Event
Log
System
Error
LED
Event
Log
Call
Home
Sense
Info
Link
Incident
✔
✔