A–41
Messages
System diagnostics
cannot run. The
Operational Status is
invalid.
System diagnostics
cannot run on switch
or Director or Edge
Switch with failed
ports.
Replace failed ports.
The add firmware
process has been
aborted.
The user aborted the
process to add a
firmware version to
the HAFM server’s
firmware library.
Verify the firmware addition is
to be aborted, then click OK
to continue.
The data collection
process failed.
An error occurred
while performing the
data collection
procedure.
Try the data collection
procedure again. If the
problem persists, contact the
next level of support.
The data collection
process has been
aborted.
The user aborted the
data collection
procedure.
Verify the data collection
procedure is to be aborted,
then click OK to continue.
The following
parameters cannot
be disabled while
Enterprise Fabric
Mode is active:
Insistent Domain ID,
Rerouting Delay,
Domain RSCN's.
A user attempted to
disable one or more
of these parameters
at the Configure
Switch Parameters
dialog box with the
switch online and
Enterprise Fabric
Mode (SANtegrity
feature) enabled.
Click Yes to continue and
disable Enterprise Fabric
Mode.
The maximum
number of address
configurations has
been reached.
The maximum
number of address
configurations that
can be saved to the
HAFM server was
reached.
Delete configurations no
longer needed to allow one or
more new address
configurations to be saved.
The optical
transceiver is not
installed.
Information is not
available for a port
without an optical
transceiver installed.
Install an SFP optical
transceiver in the port.
Message Description
Action