edge switch 2/24 service manual
2–25
Diagnostics
Figure 2–7: Monitor Panel (Log)
c. Record the event code, date, time, and severity (Informational, Minor, Major, or
Severe).
d. Record all event codes that may relate to the reported problem.
Were one or more event codes found?
NO
YES
↓
Go to
Table 2–3 on page 2-2
.
Return to the MAP step that sent you here.
51
You are at the console of an open systems interconnection (OSI) server attached to
the switch reporting the problem. If an incident occurs on the Fibre Channel link
between the switch and server, a link incident record is generated and sent to the
server using the reporting procedure defined in T11/99-017v0.
Was a link incident record generated and sent to the switch-attached OSI server?
YES
NO
↓
Perform switch fault isolation at the HAFM server (or customer-supplied
server).
Go to
step 3
.