![HP 316095-B21 - StorageWorks Edge Switch 2/24 Скачать руководство пользователя страница 101](http://html.mh-extra.com/html/hp/316095-b21-storageworks-edge-switch-2-24/316095-b21-storageworks-edge-switch-2-24_service-manual_164139101.webp)
edge switch 2/24 service manual
2–81
Diagnostics
6
Inspect the Segmentation Reason field at the Port Properties dialog box.
Table 2–15
lists port segmentation reasons and associated steps that describe fault
isolation procedures.
7
A minor error occurred that caused fabric services database to be re-initialized to an
empty state. As a result, a disruptive fabric logout and login occurred for all attached
devices. The following list explains the errors.
•
Event code 011 - The login server database failed cyclic redundancy check
(CRC) validation.
•
Event code 021 - The name server database failed CRC validation.
All attached devices resume operation after fabric login. Perform the data collection
procedure and return the Zip disk to HP for analysis. Exit MAP.
8
A minor error occurred that caused management server database to be re-initialized
to an empty state. As a result, a disruptive server logout and login occurred for all
attached devices. The following list explains the errors.
•
Event code 051 - The management server database CRC validation.
•
Event code 052 - An internal operating error was detected by the management
server subsystem.
All attached devices resume operation after management server login. Perform the
data collection procedure and return the Zip disk to HP for analysis. Exit MAP.
Table 2–15: Port Segmentation Reasons and Actions
Segmentation Reason
Action
Incompatible operating parameters.
Go to
step 14
.
Duplicate domain IDs.
Go to
step 15
.
Incompatible zoning configurations.
Go to
step 16
.
Build fabric protocol error.
Go to
step 17
.
No principal switch.
Go to
step 19
.
No response from attached switch.
Go to
step 20
.
ELP retransmission failure timeout
Go to
step 21
.