![HP 316095-B21 - StorageWorks Edge Switch 2/24 Скачать руководство пользователя страница 227](http://html.mh-extra.com/html/hp/316095-b21-storageworks-edge-switch-2-24/316095-b21-storageworks-edge-switch-2-24_service-manual_164139227.webp)
edge switch 2/24 service manual
B–13
Event Codes
Event Code: 073
Message:
Fabric initialization error.
Severity:
Informational.
Explanation:
An error was detected during the fabric initialization sequence, most likely caused by
frame delivery errors. Event data is intended for engineering evaluation.
Action:
Perform the data collection procedure and return the Zip disk to Hewlett-Packard
support personnel.
Event Data:
Byte 0 = error reason code for engineering evaluation.
Byte 1 = reserved.
Bytes 4 - 9 = port numbers for which problems were detected.
Distribution:
Switch
HAFM Server
Host
EWS
Event
Log
System
Error
LED
Event
Log
Call
Home
Sense
Info
Link
Incident
✔
✔
Event Code: 074
Message:
ILS frame delivery error threshold exceeded.
Severity:
Informational.
Explanation:
Fabric controller frame delivery errors exceeded an E_Port threshold and caused fabric
initialization problems (073 event code). Most fabric initialization problems are caused
by control frame delivery errors, as indicated by this code. Event data is intended for
engineering evaluation.
Action:
Perform the data collection procedure and return the Zip disk to Hewlett-Packard
support personnel.
Event Data:
Byte 0 = E_Port number reporting the problem.
Byte 1 = reserved.
Distribution:
Switch
HAFM Server
Host
EWS
Event
Log
System
Error
LED
Event
Log
Call
Home
Sense
Info
Link
Incident
✔
✔