2–58
edge switch 2/24 service manual
Diagnostics
27
Ensure the switch reporting the problem is connected to facility AC power. Inspect the
switch for indications of being powered on, such as:
•
At the front bezel, an illuminated green power LED or amber system error LED.
•
Audio emanations and airflow from cooling fans.
Does the switch appear powered on?
YES
NO
↓
A power distribution problem is indicated. Go to
MAP 0100: Power Distribution
Analysis on page 2-27
. Exit MAP.
28
At the switch, inspect the amber LED at the top of the CTP. Is the amber LED
illuminated on the switch?
NO
YES
↓
Failure of the CTP is indicated. Go to
MAP 0500: FRU Failure Analysis on
page 2-59
. Exit MAP.
29
Either a switch-to-PC Internet link problem (Internet too busy or
IP address typed incorrectly) or a switch Ethernet port failure is indicated.
a. Wait approximately five minutes, then attempt to login to the switch again.
b. At the Netsite field (Netscape Navigator) or Address field (Internet Explorer),
type
http://xxx.xxx.xxx.xxx
, where
xxx.xxx.xxx.xxx
is the IP address
of the switch (obtained in
MAP 0000: Start MAP on page 2-6
). The Username
and Password Required dialog box appears.
c. Type the user name and password obtained in
MAP 0000: Start MAP on
page 2-6
, and click OK. If the View panel does not display, wait five minutes and
perform this step again.
Does the EWS interface appear operational with the View panel displayed?
NO
YES
↓
The switch-to-EWS PC connection is restored and appears operational. Exit
MAP.
Failure of the switch Ethernet port is indicated. Go to
MAP 0500: FRU Failure Analysis
on page 2-59
. Exit MAP.