![HP 316095-B21 - StorageWorks Edge Switch 2/24 Скачать руководство пользователя страница 40](http://html.mh-extra.com/html/hp/316095-b21-storageworks-edge-switch-2-24/316095-b21-storageworks-edge-switch-2-24_service-manual_164139040.webp)
2–20
edge switch 2/24 service manual
Diagnostics
39
Ensure the switch reporting the problem is connected to facility AC power. Inspect the
switch for indications of being powered on, such as:
•
At the front bezel, an illuminated power LED (green) or system error LED
(amber).
•
Audio emanations and airflow from cooling fans.
Does the switch appear powered on?
YES
NO
↓
A power distribution problem is indicated. Go to
MAP 0100: Power Distribution
Analysis on page 2-27
. Exit MAP.
40
At the switch, inspect the amber LED at the switch.
Is the amber LED illuminated?
NO
YES
↓
Failure of the CTP is indicated. Event codes are not recorded. Go to
MAP
0500: FRU Failure Analysis on page 2-59
. Exit MAP.
41
A switch-to-PC Internet link problem (Internet too busy or IP address typed incorrectly)
is indicated.
a. Wait approximately five minutes, then attempt to login to the switch again.
b. At the Netsite field (Netscape Navigator) or Address field (Internet Explorer),
type
http://xxx.xxx.xxx.xxx
, where
xxx.xxx.xxx.xxx
is the IP address
of the switch (obtained in
step 1
). The Username and Password Required
dialog box appears.
c. Type the user name and password obtained in
step 1
, and click OK. If the View
panel does not display, wait another five minutes and perform this step again.
Does the EWS interface appear operational with the View panel displayed?
YES
NO
↓
Perform switch fault isolation at the HAFM server (or customer-supplied
server). Go to
step 3
.