A–40
edge switch 2/24 service manual
Messages
Send firmware failed.
A firmware download
operation failed.
Retry the firmware download
operation. If the problem
persists, contact the next level
of support.
SNMP trap address
not defined.
If an SNMP
community name is
defined, a
corresponding SNMP
trap recipient address
must also be defined.
Enter a corresponding SNMP
trap recipient address.
Stop diagnostics
failed. The test is
already running.
Diagnostics for the
port was not running
and the Stop was
selected on the Port
Diagnostics dialog
box. Diagnostics quit
for the port, but Stop
button remains
enabled.
Verify port operation. Retry
diagnostics for port and select
Stop from the dialog box. If
problem persists, contact your
service representative.
Stop diagnostics
failed. The test was
not running.
The action to stop
diagnostics failed
because the test was
not running.
Information message - no
action required.
Switch Binding was
removed from
attached devices that
are also participating
in Port Binding.
Please review the
Port Binding
Configuration.
Device WWNs were
removed from the
switch membership
list (SANtegrity
feature), but one or
more of the devices
still has security
controlled by port
binding.
Verify the security level for
each device is specified as
required by reviewing the
Bound WWN list at the
Configure Ports dialog box.
Switch must be
offline to configure.
The switch or director
must be set offline
prior to configuring
Fibre Channel
operating
parameters.
Set the switch or director
offline, reconfigure
parameters at the Configure
Operating Parameters
dialog box, and retry the
operation.
Message Description
Action