![HP 316095-B21 - StorageWorks Edge Switch 2/24 Скачать руководство пользователя страница 258](http://html.mh-extra.com/html/hp/316095-b21-storageworks-edge-switch-2-24/316095-b21-storageworks-edge-switch-2-24_service-manual_164139258.webp)
B–44
edge switch 2/24 service manual
Event Codes
Event Code: 586
Message:
Invalid primitive sequence received for current link state.
Severity:
Major.
Explanation:
An attached OSI server recognized either a link reset (LR) or a link-reset response
(LRR) sequence while in the wait-for-online sequence (OLS) state.
Action:
A LIR is generated and sent to the attached server using the reporting procedure
defined in T11/99-017v0 (OSI). If fault isolation at the server does not detect a failure,
the problem may be due to a port failure. Go to
MAP 0000: Start MAP on page 2–6
to
perform fault isolation.
Event Data:
Refer to the T11/99-017v0 document for the specific link incident record format.
Distribution:
Switch
HAFM Server
Host
EWS
Event
Log
System
Error
LED
Event
Log
Call
Home
Sense
Info
Link
Incident
✔
✔