B–11
Event Codes
Event Code: 070 (continued)
Distribution:
Switch
HAFM Server
Host
EWS
Event
Log
System
Error
LED
Event
Log
Call
Home
Sense
Info
Link
Incident
✔
✔
Event Code: 071
Message:
Switch is isolated.
Severity:
Informational.
Explanation:
The switch is isolated from other fabric elements (Director or Edge Switch). This event
code is accompanied by one or more 070 event codes. Refer to the event data for the
segmentation reason.
Action:
Action depends on the segmentation reason specified in the event data.
Event Data:
The first byte of event data (byte 0) specifies the E_Port number. The fifth byte (byte 4)
specifies the segmentation reason as follows:
1 = Incompatible operating parameters. Ether the resource allocation time out value
(R_A_TOV) or error detect time out value (E_D_TOV) is inconsistent between the switch
and another fabric element (Director or Edge Switch). Modify the R_A_TOV and
E_D_TOV to make the values consistent for all fabric Directors and Edge Switches.
2 = Duplicate domain ID. The switch has the same preferred domain ID as another
fabric element (Director or Edge Switch). Modify the switch’s Domain ID to make it
unique.
3 = Incompatible zoning configurations. The same name is applied to a zone for the
switch and another fabric element (Director or Edge Switch), but the zones contain
different zone members. Modify the zone name to make it unique, or ensure zones with
the same name contain identical zone members.