2–36
edge switch 2/24 service manual
Diagnostics
3
Table 2–5
lists event codes, brief explanations of the codes, and the associated steps
that describe fault isolation procedures.
4
POST/IPL diagnostics detected a FRU failure as indicated by an event code 400 with
supplementary event data.
a. At the Hardware View, click Logs and select Event Log. The Event Log
displays.
b. Examine the first two bytes (0 and 1) of event data.
c. Byte 0 is a FRU code that indicates the failed component. Byte 1
is the slot number of the failed FRU (00 for a nonredundant FRU, and 00 or 01 for
redundant FRUs.
Table 2–6
lists byte 0 FRU codes and associated steps that describe fault
isolation procedures.
Table 2–5: MAP 200: Event Codes
Event
Code
Explanation
Action
400
Power-up diagnostic failure.
Go to
step 4
.
411
Firmware fault.
Go to
step 7
.
Table 2–6: MAP 200: Byte 0 FRU Codes
Byte 0
Failed FRU
Action
02
CTP.
Go to
step 6
.
05
Fan module.
Go to
step 5
.
06
Power supply.
Go to
step 6
.