edge switch 2/24 service manual
B–21
Event Codes
Fan Module Events (300 through 399)
Event Code: 300
Message:
Cooling fan propeller failed.
Severity:
Major.
Explanation:
One cooling fan (out of six) failed or is rotating at insufficient angular velocity. The
remaining fans are operational. The amber LED illuminates at the rear of the power
supply assembly associated with the failed fan.
Action:
Replace the power supply assembly containing the indicated fan module.
Event Data:
The first byte of event data (byte 0) specifies the failed fan number (0 through 5
inclusive).
Distribution:
Switch
HAFM Server
Host
EWS
Event
Log
System
Error
LED
Event
Log
Call
Home
Sense
Info
Link
Incident
✔
✔
✔
✔
✔
✔
Event Code: 301
Message:
Cooling fan propeller failed.
Severity:
Major.
Explanation:
Two cooling fans (out of six) failed or are rotating at insufficient angular velocity. The
remaining fans are operational. The amber LED illuminates at the rear of the power
supply assembly (or assemblies) associated with the failed fans.
Action:
Replace the power supply assembly (or assemblies) containing the indicated fan
modules.
Event Data:
The first byte of event data (byte 0) specifies the failed fan numbers (0 through 5
inclusive).
Distribution:
Switch
HAFM Server
Host
EWS
Event
Log
System
Error
LED
Event
Log
Call
Home
Sense
Info
Link
Incident
✔
✔
✔
✔
✔
✔