168
....... ........
Setting Parameters
* = Factory adjusted mod
e
Start the measuring run by closing the wheel
guard
Off =
Start via START key
On* =
Start via wheel guard
The selected operating mode can be acquired in
the permanent memory.
Automatic braking when the wheel guard is
raised
Off =
No braking
Note
:
When the guard is lifted, the wheel is not braked
and continues to rotate from inertia.
Make sure that the wheel is not blocked by a tool
or similar item.
WEAR SAFETY GOGGLES AND TIGHTLY FITTING
WORKING CLOTHES.
On*
=
Braking
The selected operating mode can be acquired in
the permanent memory.
Adjusting the DATE/TIME COUNTERS
After selecting the “Date adjustment”, in the
SETTINGS screen, a keyboard is displayed with the
data entry field.
Enter the date as follows;
Year / Month / Day (yyyy/mm/dd).
Note:
A different structure set by the operator does not
affect the setting sequence.
After selecting the “Time adjustment”, in the SETTINGS
screen, a keyboard is displayed with the data entry
field.
Enter the time as follows;
Hours / Minutes.
Note:
Changes to the date and time are immediately
active and are retained when the machine is
next started without needing to be saved to the
permanent memory.
....... ........