Setting Parameters
* = Factory adjusted mod
e
Resolution of the unbalance amount readings
Selecting the resolution of unbalance readings in
1 or 5 g, or 0.05 or 0.25 oz increments.
Normal*
=
5 g ( 0 . 2 5 o z )
increments
Fine
=
1 g ( 0 . 0 5 o z )
increments
The selected operating mode can be acquired in
the permanent memory.
Suppression of minor unbalance amount
readings
Off =
Suppression off
On * =
Suppression on
The selected operating mode can be acquired in
the permanent memory.
Setting threshold value for unbalance
suppression in grams or ounces
Selecting the limit (threshold) value for suppression
of minor unbalance readings in grams, or ounces.
The unit of measurement depends on the settings
made under “Measurement unit of the unbalance
amount readings” (see below).
Unit of measurement
grams
:
Range 3.50 to 20.0 g
Factory–adjusted to 3.5 g
Unit of measurement
ounces
:
Range 0.25 to 2.00 oz
Factory–adjusted to 0.25 oz
The selected operating mode can be acquired in
the permanent memory.
Measurement unit of the unbalance amount
readings
Selecting unbalance readings in grams or ounces,
active when the machine is switched on.
GRAMS*
=
readings in grams
OUNCES =
readings in ounces
The selected operating mode can be acquired in
the permanent memory.
Number of revolutions for each run
5 to 20 revolutions possible for each run.
Factory–adjusted to 10.*
The selected operating mode can be acquired in
the permanent memory.
Warning
Reducing the number of measurement revolutions
will reduce the accuracy of measurement.
....... ........