![Hitachi RCI-1.0FSR Скачать руководство пользователя страница 124](http://html.mh-extra.com/html/hitachi/rci-1-0fsr/rci-1-0fsr_service-manual_2139379124.webp)
5 Optional functions
Optional functions through Remote control
SMGB0137 rev.0 - 05/2021
114
Element
Optional function
Individual
setting
Settings
Setting conditions
Description
E8
Control for stop of the
indoor unit fan during
heating Thermo-OFF
conditions (with remote
sensor THM-R2AE
connected to the THM4
connector in the indoor
unit PCB)
O
00
Fan operation in Low speed
This function stops the fan
to prevent cold draughts or
overheating.
C8 must be set to 01 to use the
E8=01 setting.
The connection of a THM-R2AE
remote temperature sensor to
the THM4 port in the indoor unit
PCB is required. The remote
sensor shall be installed in a
proper place for the correct
detection of room temperature.
(In case that automatic louvre
is set, the louvre will keep
operating in both Thermo-ON
and Thermo-OFF condition.)
01
Fan stop in Thermo-OFF conditions
E9
Intermittent fan operation
in heating stop
Not available for models:
RPF(I)-FSN2E
O
00
Function disabled
(factory setting)
In case that indoor unit operation
is set OFF by the remote control
switch, under certain conditions
the fan is operated in cycles
consisting of 3 minutes of
operation at SLow speed and
30 minutes of stoppage.
01
Function enabled
EA
Not used
–
00
-
Use at 00 conditions
01
02
Eb
Indoor unit fan control
during cooling
Thermo-OFF conditions
O
00
Function disabled
(factory setting)
This function decreases speed
of the indoor unit fan during
cooling Thermo-OFF, to reduce
the spread of smells and
humidity.
01
Low
02
Slow
EC
Forced Thermo-ON
when stopping in cooling
operation
O
00
Function disabled
(factory setting)
This function is used to force
Thermo-ON during 6 minutes
when stopping in cooling
operation.
01
Enabled
Ed
Not used
O
00
-
Use at 00 conditions
01
EE
Control in “Automatic”
indoor fan speed mode
O
00
Function disabled
(factory setting)
This function limits the speed
of the indoor fan when room
temperature is close to the
setting temperature.
01
Enabled
EF
Control in “Automatic”
indoor fan speed mode
(supporting High H)
Models:
RCI-FSR
RCIM-FSRE
RCD-FSR
RPC-FSR
RPI(L/H)-FSRE
RPI-FSN3E(P)E(-f)
RPK-FSR(H)M
O
00
Function disabled
This function limits the speed
of the indoor fan when room
temperature is close to the
setting temperature, allowing to
reach High H speed.
01
Function enabled
F0
Not available
–
“- -”
permanent –
–