413
•
Bit 3 (Clock Select (CKS)): CKS selects the A/D conversion time. The conversion time should
be changed only when the ADST bit is cleared to 0.
Bit 3 (CKS)
Description
0
Conversion time = 266 states (maximum)
(Initial value)
1
Conversion time = 134 states (maximum)
•
Bits 2–0 (Channel Select 2–0 (CH2–CH0)): CH2–CH0 select analog input channels together
with the SCAN bit. The channel selection should be changed only when the ADST bit is
cleared to 0.
Group Select
Channel Select
Selected Channels
CH2
CH1
CH0
Single Mode
Scan Mode
0
0
0
AN0
AN0 (Initial value)
0
1
AN1
AN0 and AN1
1
0
AN2
AN0–AN2
1
1
AN3
AN0–AN3
1
0
0
AN4
AN4
0
1
AN5
AN4 and AN5
1
0
AN6
AN4–AN6
1
1
AN7
AN4–AN7
14.2.3
A/D Control Register (ADCR)
The A/D control register (ADCR) is an 8-bit read/write register that selects whether or not to start
the A/D conversion when an external trigger is input. ADCR is initialized to H'7F by a reset and in
standby mode.
Bit:
7
6
5
4
3
2
1
0
Bit name:
TRGE
—
—
—
—
—
—
—
Initial value:
0
1
1
1
1
1
1
1
R/W:
R/W
—
—
—
—
—
—
—
Содержание HD6417032
Страница 21: ......
Страница 35: ...xiv ...
Страница 85: ...50 ...
Страница 101: ...66 ...
Страница 129: ...94 ...
Страница 135: ...100 ...
Страница 343: ...308 ...
Страница 369: ...334 ...
Страница 383: ...348 ...
Страница 475: ...440 ...
Страница 525: ...490 CK RAS CAS TRp TRc TRcc tRASD1 tRASD2 tCASD3 tCASD2 TRr tCSR Figure 20 18 Self Refresh ...
Страница 578: ...543 CK RAS CAS TRp TRc TRcc tRASD1 tRASD2 tCASD3 tCASD2 TRr tCSR Figure 20 62 Self Refresh ...
Страница 689: ...654 ...