242
10.2.9
Timer Control Register (TCR)
The ITU has five 8-bit timer control registers (TCR), one for each channel.
TCR is an 8-bit read/write register that selects the timer counter clock, the edges of the external
clock source, and the counter clear source. TCR is initialized to H'80 or H'00 by a reset and in
standby mode.
Table 10.7
Timer Control Register (TCR)
Channel
Abbrevi-
ation
Function
0
TCR0
1
TCR1
2
TCR2
3
TCR3
4
TCR4
Bit:
7
6
5
4
3
2
1
0
Bit name:
—
CCLR1
CCLR0
CKEG1
CKEG0
TPSC2
TPSC1
TPSC0
Initial value:
*
0
0
0
0
0
0
0
R/W:
—
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Note:
*
Undefined
•
Bit 7 (Reserved): Bit 7 is read as undefined. The write value should be 0 or 1.
TCR controls the TCNTs. The TCRs have the same functions on all channels.
When channel 2 is set for phase counting mode, setting the CKEG1, CKEG2,
and TPSC2–TPSC0 bits will have no effect.