6. Click Save.
• The configured parameters will be applied to the device
automatically.
• After changing the working mode or connection mode, the
device will reboot automatically.
Set Wiegand Parameters
You can set the access control device's Wiegand channel and the
communication mode. After setting the Wiegand parameters, the
device can connect to Wiegand card reader via Wiegand
communication.
Steps
Note
This function should be supported by the device.
1. Enter the Access Control module.
2. On the navigation bar on the left, enter Advanced Function
More Parameters .
3. Select an access control device in the device list and click
Wiegand to enter the Wiegand Settings page.
4. Set the switch to on to enable the Wiegand function for the
device.
5. Select the Wiegand channel No. and the communication mode
from the drop-down list.
Note
If you set Communication Direction as Sending, you are
required to set the Wiegand Mode as Wiegand 26 or Wiegand
34.
6. Click Save.
• The configured parameters will be applied to the device
automatically.
• After changing the communication direction, the device will
reboot automatically.
Enable M1 Card Encryption
M1 card encryption can improve the security level of
authentication.
Steps
Note
The function should be supported by the access control device
and the card reader.
1. Enter the Access Control module.
2. On the navigation bar on the left, enter Advanced Function
More Parameters .
3. Select an access control device in the device list and click M1
Card Encryption to enter the M1 Card Encryption page.
4. Set the switch to on to enable the M1 card encryption
function.
5. Set the sector ID.
The sector ID ranges from 1 to 100.