Door Contact
You can set the door sensor as remaining closed or
remaining open. Usually, it is remaining closed.
Exit Button Type
You can set the exit button as remaining closed or remaining
open. Usually, it is remaining open.
Door Locked Time
After swiping the normal card and relay action, the timer for
locking the door starts working.
Extended Open Duration
The door contact can be enabled with appropriate delay
after person with extended accesss needs swipes her/his
card.
Door Open Timeout Alarm
The alarm can be triggered if the door has not been closed
in a configured time period. If it is set as 0, no alarm will be
triggered.
Lock Door when Door Closed
The door can be locked once it is closed even if the Door
Locked Time is not reached.
Duress Code
The door can open by inputting the duress code when there
is duress. At the same time, the client can report the duress
event.
Super Password
The specific person can open the door by inputting the super
password.
Dismiss Code
Create a dismiss code which can be used to stop the buzzer
of the card reader (by entering the dismiss code on the
keypad).
Note
• The duress code, super code, and dismiss code should be
different.
• The duress code, super password, and the dismiss code
should be different from the authentication password.
• The length of duress code, super password, and the dismiss
code is according the device, usually it should contains 4 to 8
digits.
5. Click OK.
6. Optional: Click Copy to , and then select the door/floor(s) to
copy the parameters in the page to the selected doors/floor(s).
Note
The door or floor's status duration settings will be copied to
the selected door/floor(s) as well.
Configure Parameters for Card Reader
After adding the access control device, you can configure its card
reader parameters.
52
Содержание DS-K1T605 Series
Страница 1: ...Face Recognition Terminal UD07930B E...
Страница 104: ...95...
Страница 105: ...C Relationship between Device Height Person Height and Standing Distance 96...
Страница 107: ...E Dimension 98...