1/3/05
WARNING: Disconnect primary power prior to servicing.
eCDi ™
Section 3 Operation
3.6.2
Performance Faults Screen
There are 2 alarms on the Performance monitoring Faults screen shown in Figure 3-20.
•
Shoulder Compliance (default = 47dB)
•
SNR (default = 27dB)
Figure 3-20 Performance - Faults Screen
These alarm levels can be modified by the user, from the default levels noted above, by
going to the Browser Menus and selecting Configuration
?
Perf Monitoring (this
requires the administrator password, see "2.8 eCDi™ Configuration" on page 2-26).
This will open the screen in Figure 3-21. Directly edit the numbers and press Submit
and then Apply on the main configuration screen.
Содержание eCDi
Страница 4: ...MRH 2 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing...
Страница 6: ...vi 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing...
Страница 8: ...viii 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing...
Страница 12: ...xii 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing...
Страница 96: ...4 4 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing eCDi Section 4 Software Updates...
Страница 98: ...5 2 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing eCDi Section 5 Interconnect Diagram...
Страница 100: ...5 4 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing eCDi Section 5 Interconnect Diagram...
Страница 102: ...5 6 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing eCDi Section 5 Interconnect Diagram...
Страница 104: ...5 8 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing eCDi Section 5 Interconnect Diagram...
Страница 106: ...5 10 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing eCDi Section 5 Interconnect Diagram...
Страница 108: ...5 12 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing eCDi Section 5 Interconnect Diagram...
Страница 110: ...5 14 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing eCDi Section 5 Interconnect Diagram...
Страница 112: ...5 16 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing eCDi Section 5 Interconnect Diagram...
Страница 120: ...6 8 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing eCDi Section 6 SNMP Connectivity...
Страница 136: ...A 12 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing eCDi Appendix A SigmaCD Fault and Meter...
Страница 154: ...C 10 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing eCDi Appendix C Atlas Fault and Meter Log...
Страница 162: ...D 8 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing eCDi Appendix D Ranger Fault and Meter...
Страница 172: ...E 10 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing eCDi Appendix E Platinum TV Fault and...