1/3/05
888-2517-001
2-15
WARNING: Disconnect primary power prior to servicing.
Section 2 Installation & Setup
eCDi ™
NOTE:
When routing the serial cable to the back of the exciters, make sure to follow the
cable supports and wiring harness to allow the exciters to be pulled completely
out the front to the extent of the rack slides. Cable ties should be used to secure
the serial cable to prevent damage when the exciter is pulled out for service.
b.
Connect the provided Y adaptor to the ends of
both 10ft. cables. Two (2) stand-off kits are
provided and should be attached to the Y adap-
tor cable as shown here.
c.
Connect the supplied 50ft. cable labeled
“Exciter” from the Y adaptor “Exciter” port to the serial port labeled “Exciter” on
the eCDi™ unit.
NOTE:
The exciters can both be connected to the same serial cable because they only
have access to the serial port if they are the active or ON-AIR exciter in the
transmitter.
IMPORTANT:
If there is only one (1) CD-1A exciter to be connected, then simply omit the “Y”
splitter cable in the previous instructions and connect the 50ft. eCDi™ serial
cable labeled “Exciter” directly from the eCDi™ unit to the exciter.
Figure 2-11 Connection Drawing for Dual CD-1A Exciters
Y Adaptor
with Stand-offs
Exciter A
CD-1A
RS232
Exciter B
CD-1A
RS232
Exciter Port
eCDi™
Y Adaptor Cable
10ft. Serial Cable
10ft. Serial Cable
50ft. Serial Cable
NOTE: Be sure to route these cables
along the existing wiring harness
to the exciters
NOTE: attach the standoff kits to the Y
adaptor cable. This allows the serial cables to
be secured directly to the Y adaptor.
Содержание eCDi
Страница 4: ...MRH 2 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing...
Страница 6: ...vi 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing...
Страница 8: ...viii 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing...
Страница 12: ...xii 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing...
Страница 96: ...4 4 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing eCDi Section 4 Software Updates...
Страница 98: ...5 2 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing eCDi Section 5 Interconnect Diagram...
Страница 100: ...5 4 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing eCDi Section 5 Interconnect Diagram...
Страница 102: ...5 6 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing eCDi Section 5 Interconnect Diagram...
Страница 104: ...5 8 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing eCDi Section 5 Interconnect Diagram...
Страница 106: ...5 10 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing eCDi Section 5 Interconnect Diagram...
Страница 108: ...5 12 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing eCDi Section 5 Interconnect Diagram...
Страница 110: ...5 14 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing eCDi Section 5 Interconnect Diagram...
Страница 112: ...5 16 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing eCDi Section 5 Interconnect Diagram...
Страница 120: ...6 8 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing eCDi Section 6 SNMP Connectivity...
Страница 136: ...A 12 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing eCDi Appendix A SigmaCD Fault and Meter...
Страница 154: ...C 10 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing eCDi Appendix C Atlas Fault and Meter Log...
Страница 162: ...D 8 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing eCDi Appendix D Ranger Fault and Meter...
Страница 172: ...E 10 888 2517 001 1 3 05 WARNING Disconnect primary power prior to servicing eCDi Appendix E Platinum TV Fault and...