WARNING: Disconnect primary power prior to servicing.
Section 2 Installation / Initial Turn-On
ATLAS Analogue
2.15.1 Remote Power Metering, J17
Each analog metering output will provide 0 - 4.096Vdc output into a 400 ohm load
(where 3Vdc = Full Scale). The connections for J17 are listed in Table 2-13.
Table 2-13 J17, External I/O Board, Remote Power Metering
Connection
Schematic Label
Metered Parameter
J17-1
GND
Ground
J17-2
VOUTA
Total Forward Visual Power (after filter)
J17-3
VOUTB
Total Reflected Power (after filter)
J17-4
VOUTC
Forward Visual Power Cabinet #1 (before filter)
J17-5
VOUTD
Reflected Power Cabinet #1 (before filter)
J17-6
GND
Ground
J17-7
GND
Ground
J17-8
VOUTE
Forward Visual Power Cabinet # 2(before filter)
J17-9
VOUTF
Reflected Power Cabinet #2 (before filter)
J17-10
VOUTG
Forward Visual Power Cabinet #3 (before filter)
J17-11
VOUTH
Reflected Power Cabinet #3 (before filter)
J17-12
GND
Ground