7/26/05
888-2523-001
2-39
WARNING: Disconnect primary power prior to servicing.
Section 2 Installation / Initial Turn-On
ATLAS Analogue
momentary ground switching and require the remote control equipment to sink at least
15mA to activate the function. The Pinouts of J13 and J14 are listed in Table 2-11.
Table 2-11 J13 & J14, External I/O Board, Remote Control Connectors
Connector
and pin #
Schematic
Label
Function
Command Type and
Polarity
J13-1
GND
GROUND
J13-2
/INPUT 1
Remote ON
Pulsed LOW
J13-3
/INPUT 2
Remote OFF
Pulsed LOW
J13-4
/INPUT 3
Remote RAISE Power
Pulsed LOW
J13-5
/INPUT 4
Remote LOWER Power
Pulsed LOW
J13-6
GND
GROUND
J13-7
GND
GROUND
J13-8
/INPUT 5
Remote Drive Chain A/B Select
Pulsed LOW to toggle
J13-9
/INPUT 6
Remote RF Mute ON
L= RF Muted
H= RF NOT Muted
J13-10
/INPUT 7
Remote Pump A/B Select
Pulsed LOW to toggle
J13-11
/INPUT 8
Spare
J13-12
GND
GROUND
J14-1
GND
GROUND
J14-2
/INPUT 9
Remote External RF Switch A/B Select
Pulsed LOW to toggle
J14-3
/INPUT 10
RF Switch Position A Status from switch
L= POSITION A
H= NOT POSITION A
J14-4
/INPUT 11
RF Switch Position B Status from switch
L= POSITION B
H= NOT POSITION B
J14-5
/INPUT 12
Remote Drive AUTO/MANUAL Select
Pulsed LOW to toggle
J14-6
GND
GROUND
J14-7
GND
GROUND
J14-8
/INPUT 13
Remote Pump AUTO/MANUAL Select
Pulsed LOW to toggle
J14-9
/INPUT 14
SPARE
J14-10
/INPUT 15
SPARE
J14-11
/INPUT 16
SPARE
J14-12
GND
GROUND
Содержание ATLAS ANALOGUE
Страница 4: ...iv 888 2523 001 7 26 05 WARNING Disconnect primary power prior to servicing...
Страница 6: ...vi 888 2523 001 7 26 05 WARNING Disconnect primary power prior to servicing...
Страница 8: ...viii 888 2523 001 7 26 05 WARNING Disconnect primary power prior to servicing...
Страница 10: ...x 888 2523 001 7 26 05 WARNING Disconnect primary power prior to servicing...
Страница 14: ...Table of Contents continued 4...
Страница 114: ...3 40 888 2523 001 7 26 05 WARNING Disconnect primary power prior to servicing Section 3 Operation ATLAS Analogue...