2-28
888-2523-001
7/26/05
WARNING: Disconnect primary power prior to servicing.
Section 2 Installation / Initial Turn-On
ATLAS Analogue
2.12 Install PA Modules
Be sure the PA power supply breakers (on the mid deck in rear) are in the OFF
position.
!
WARNING:
THE PA MODULES ARE LARGE AND RELATIVELY HEAVY, WEIGHING SLIGHTLY
LESS THAN 25KG. CARE SHOULD BE TAKEN TO AVOID PERSONAL INJURY AND/
OR DAMAGE TO THE MODULES.
Remove the shipping foam packing surrounding the hose connectors in rear PA
cabinet by performing the following procedure.
a.
Carefully pull each top blue hose from foam
b.
While lifting and holding foam, pull remaining green bottom hoses from foam
c.
Remove foam piece from cabinet
d.
Vacuum foam remnants in cabinet
Unpack and install the PA modules into the front of the transmitter cabinet. Be
sure to position the module so the hose connections are near the bottom.
NOTE:
The PA Modules should be placed into the same slot in which they were tested at
the factory. Each module has a serial number tag. This serial number is recorded
on the factory test data sheet along with the appropriate slot number. Placing the
module in a different slot will not cause any harm to the transmitter but will
require more time for module phasing.
Connect the Coolant hoses to the rear of the PA
Modules. Green hoses on the bottom and blue hoses on
the top. Push the hose coupling on to the module nipple
until it locks into place. Make sure the coolant valves on
the couplers are in the open position as shown here.
Turning the valve at a right angle to the hose shuts off
flow to the module.
NOTE:
It is helpful to have an assistant maintain pressure on the module from the front
of the transmitter as the coolant hoses are being attached in the rear.
Coolant
Valve
(shown
open)
Содержание ATLAS ANALOGUE
Страница 4: ...iv 888 2523 001 7 26 05 WARNING Disconnect primary power prior to servicing...
Страница 6: ...vi 888 2523 001 7 26 05 WARNING Disconnect primary power prior to servicing...
Страница 8: ...viii 888 2523 001 7 26 05 WARNING Disconnect primary power prior to servicing...
Страница 10: ...x 888 2523 001 7 26 05 WARNING Disconnect primary power prior to servicing...
Страница 14: ...Table of Contents continued 4...
Страница 114: ...3 40 888 2523 001 7 26 05 WARNING Disconnect primary power prior to servicing Section 3 Operation ATLAS Analogue...