ATLAS Analogue
Figure 3-30 System Service Screen
3.9.4.1
System Setup
This screen provides a way to change 3 important pieces of information which are then
used throughout the GUI.
•
Station Name: This can be up to 24 characters and will appear at the top of every
GUI screen
•
Model Number: This value is selected from a pull down list by touching the white
box. The model number chosen must match the transmitter name plate. It is used to
gray out portions of the GUI screens which are not used by some models.
•
Nom. Power Output: This is typically the nominal licensed power after all system
filters, and used for a couple of things:
•
It is used to set the 100% mark on the power bargraphs at the top of every
GUI screen
•
It is used as part of the calculation of the VSWR foldback and fault
thresholds, see "5.5 Power Calibrations" on page 5-8 of this manual
The rest of the information on this page includes:
•
Serial Number: (cannot be changed by user) - Please note this for reference before
calling for support
•
Nominal AC Line: This number should reflect your nominal AC line voltage (VAC)
as measured at the disconnect
To Figure 3-31
To Figure 3-35
To Figure 3-36
To Figure 3-23
Содержание ATLAS ANALOGUE
Страница 4: ...iv 888 2523 001 7 26 05 WARNING Disconnect primary power prior to servicing...
Страница 6: ...vi 888 2523 001 7 26 05 WARNING Disconnect primary power prior to servicing...
Страница 8: ...viii 888 2523 001 7 26 05 WARNING Disconnect primary power prior to servicing...
Страница 10: ...x 888 2523 001 7 26 05 WARNING Disconnect primary power prior to servicing...
Страница 14: ...Table of Contents continued 4...
Страница 114: ...3 40 888 2523 001 7 26 05 WARNING Disconnect primary power prior to servicing Section 3 Operation ATLAS Analogue...