7/26/05
888-2523-001
1-11
WARNING: Disconnect primary power prior to servicing.
Section 1 Introduction
ATLAS Analogue
Figure 1-6
Simplified Liquid Cooling System Block Diagram
1.2.6.3
Heat Exchanger
The heat exchanger, which is typically installed outside, has 2 or 3 fans depending on
transmitter model. The fans are enabled whenever the pump module is activated, but
temperature sensors determine when the fans will actually start. The first fan is factory
set to turn on when the coolant temperature reaches 32
o
C with the second one turning
on at 38
o
C; these settings are adjustable.
1.2.6.4
Transmitter Cold Plates
Each PA Module has an attached liquid cooled cold plate which connects to the cooling
system with flexible hoses and quick release connectors. There is also a separate cold
plate mounted inside the transmitter cabinet to which all of the internal combiner reject
loads are attached. See Figure 1-7.