3-14
888-2523-001
7/26/05
WARNING: Disconnect primary power prior to servicing.
Section 3 Operation
ATLAS Analogue
Figure 3-11 More PA Meters Screen
PA Module will fault off with any of the following maximum temperatures shown
under the Module Temperatures heading: "Heatsink" @ 70°C; "PS Bd" @ 95°C;
"Control Bd" @ 95°C
3.6.3
PA Service
This screen is accessed by pressing the "PA Service" button in Figure 3-7. This screen
allows individual PA modules to be turned on or off. The primary purpose of this screen
is to turn off a PA module for removal. It will also allow only a single module to be
turned on for troubleshooting purposes. The 8 PA Module buttons in the middle of the
screen are toggle switches. Press it once and the PA module shuts off. Press it again and
the module turns on. The front panel ON button can also be used to reactivate a module,
but should only be used when you want all modules on.
When taking
readings, be sure
to note the PA
Module Number
and Cabinet
Number
Содержание ATLAS ANALOGUE
Страница 4: ...iv 888 2523 001 7 26 05 WARNING Disconnect primary power prior to servicing...
Страница 6: ...vi 888 2523 001 7 26 05 WARNING Disconnect primary power prior to servicing...
Страница 8: ...viii 888 2523 001 7 26 05 WARNING Disconnect primary power prior to servicing...
Страница 10: ...x 888 2523 001 7 26 05 WARNING Disconnect primary power prior to servicing...
Страница 14: ...Table of Contents continued 4...
Страница 114: ...3 40 888 2523 001 7 26 05 WARNING Disconnect primary power prior to servicing Section 3 Operation ATLAS Analogue...