2-36
888-2523-001
7/26/05
WARNING: Disconnect primary power prior to servicing.
Section 2 Installation / Initial Turn-On
ATLAS Analogue
Verify that the reflected power at each PA module is under 50 watts. The PA Meters
screen shows the forward and reflected power for each PA Module. Press the BACK
button.
All PAs should show a green (OK) status indication on the GUI (Power Amp
screen).
Press OUPUT then OUTPUT METERS. This page shows the forward and reflected
powers for the Cabinet and Total System power. The VSWR is also indicated.
Slowly bring up the transmitter power by pressing the RAISE button on front
panel to the nominal value, as indicated by the bar graphs. Monitor the cabinet
forward and reflected powers, as well as the VSWR reading. A large VSWR (above
1.1) is indicative of a bad RF connection to the test load.
Check PA Module (and multi-cabinet) Phasing. See "5.4 PA Module Phasing" on
page 5-6 for steps to observe the below screen. If any of the PA Module (or cabinet)
reject load sample levels are above 0030, proceed to "5.4.2 Module Phasing Procedure"
on page 5-7 for details on adjusting levels.
Figure 2-7 Module Phasing screen
(multi-cabinet model shown)
Verify that the transmitter meter readings are close to the factory test data meter
readings, mainly all of the current and voltage readings.
Perform an Auto Bias procedure. See "5.3 PA Module Auto Bias Procedure" on page
5-5 for more information. Due to natural drift of LDMOS devices with age, periodic re-
biasing of the pallets within the modules is recommended. However, this procedure has
Detected RF sample
level, 0000 - 1023
PA Module Phase
Control Voltage
0000 - 1023
GOAL: To get the
detected RF
sample level
readings below
0030 (with
Gain set to LOW)
Module Group
select buttons
Reject Loads
Содержание ATLAS ANALOGUE
Страница 4: ...iv 888 2523 001 7 26 05 WARNING Disconnect primary power prior to servicing...
Страница 6: ...vi 888 2523 001 7 26 05 WARNING Disconnect primary power prior to servicing...
Страница 8: ...viii 888 2523 001 7 26 05 WARNING Disconnect primary power prior to servicing...
Страница 10: ...x 888 2523 001 7 26 05 WARNING Disconnect primary power prior to servicing...
Страница 14: ...Table of Contents continued 4...
Страница 114: ...3 40 888 2523 001 7 26 05 WARNING Disconnect primary power prior to servicing Section 3 Operation ATLAS Analogue...