WARNING: Disconnect primary power prior to servicing.
Section 3 Operation
ATLAS Analogue
Figure 3-10 PA Metering Screen
PA Module will fault off at 100W "Prefld(W)" reflected power. Also, it will fault off at
70° C temperature.
NOTE:
The PA output powers displayed under the PA Meters heading are not peak sync
power, but the power at blanking level. Peak sync power is obtained by multiply-
ing the blanking level (displayed) power by one the following factors:
•
1.68 for System M/NTSC
•
1.72 for PAL TV systems using 15% residual carrier
•
1.77 for PAL TV systems using 10% residual carrier
To Figure 3-11