WARNING: Disconnect primary power prior to servicing.
Section 2 Installation / Initial Turn-On
ATLAS Analogue
If there is a temperature overload switch on the test load, (as would be the case for
an air cooled load) it should be connected to J18-11 and J18-12. This open interlock
contact will mute the transmitter RF output if the test load temperature threshold is
exceeded (while the transmitter is operating into the test load). A jumper is installed at
the factory which must be removed to use this input.
NOTE:
Patch Panel status signals will tell the Main Controller to ignore this interlock if
the transmitter output is currently routed into the antenna.