background image

i

Paragon-III (700MHz) 

Data Base Station

(With Amplifier Technologies 70W PA)

User Manual 

Version 1.00a

Preliminary – For Internal Use Only

The entire contents of this manual are copyright 2005 by 

DATARADIO

 Inc.

Copyright 

DATARADIO

 Inc.

April 2005

Part no.: 120 20191-100a

Содержание Paragon-III

Страница 1: ...Station With Amplifier Technologies 70W PA User Manual Version 1 00a Preliminary For Internal Use Only The entire contents of this manual are copyright 2005 by DATARADIO Inc Copyright DATARADIO Inc Ap...

Страница 2: ...3 OPERATING DESCRIPTION 11 3 1 RADIO ASSEMBLY 11 Diversity SDR Rx module 11 3 1 2 5W Transmitter module 12 3 1 3 70W Power Amplifier 12 3 1 4 BSC module 13 3 1 5 Speaker panel 13 3 1 6 Power Supply Mo...

Страница 3: ...E 6 BACKPLANE 7 FIGURE 7 MAXI FUSE 9 FIGURE 8 RECEIVER MODULE 11 FIGURE 9 5W EXCITER MODULE 12 FIGURE 10 BSC MODULE 13 FIGURE 11 SPEAKER MODULE 13 FIGURE 12 T 809 POWER SUPPLY MODULE 14 FIGURE 13 T809...

Страница 4: ...P OPTIMIZATION TUNING 24 TABLE 12 SIMPLE NETWORK TIME PROTOCOL 24 TABLE 13 SECURITY 24 TABLE 14 NETWORK 24 TABLE 15 PACKET STATISTICS 25 TABLE 16 RF TEST 25 TABLE 17 FTP TRANSFER 25 TABLE 18 RSSI TABL...

Страница 5: ...HAT S NEW History Version 1 00a April 2005 Preliminary With optional Amplifier Technologies 70W PA Version 0 02 October 2004 issue 0 02 preliminary With optional Aethercomm 50W PA as Annex A Version 0...

Страница 6: ...ixed point to point and point to multi point applications and OEMs Our product line is one of the broadest in the industry covering the most often used frequency bands www dataradio com Dataradio prov...

Страница 7: ...ows based Commands Data over IP radio modem Software This soft ware allows basic tests unit configuration and troubleshooting COM Port RS 232 serial communications ports of the Paragon III wireless ra...

Страница 8: ...of application related information in a wireless communications system Paragon III IP based data radio base station used in mobile networks and designed specifi cally to fit the needs of vehicular ap...

Страница 9: ...that is sent Upgrade To replace existing software or firmware with a newer version URL Universal Resource Locator The address of a file located on the Internet VIS Vehicular Information Solutions Dat...

Страница 10: ...ta decode sensitivity in multi path and fading environments When used with Dataradio s state of the art Gemini G3 mobile IP data solution the system delivers unequaled high speed data performance and...

Страница 11: ...band Base Station with 70W RF Power Amplifier user adjustable from 35W On air data speeds and modulation types supported Table 1 On air data speeds and modulation types Modulation type Channel spacing...

Страница 12: ...al customers DATARADIO Inc 5500 Royalmount Ave suite 200 Town of Mount Royal Quebec Canada H4P 1H7 Technical support hours Monday to Friday 9 00 AM to 5 00 PM Eastern Time phone 1 514 737 0020 fax 1 5...

Страница 13: ...d a question arise during servicing of the unit Customers are responsible for shipping charges for returned units Units in warranty will be repaired free of charge unless there is evidence of abuse or...

Страница 14: ...This manual covers the radio modem assembly and the power amplifier 2 2 Location Be sure to place the Paragon III in such a way that The LEDs can be seen as an aid in troubleshooting Access to the ant...

Страница 15: ...ser Manual 6 Figure 2 Amplifier Technologies Inc 70W Power Amplifier Figure 3 Indicators and Power Adjustment Control Figure 4 Power Amplifier s DC Power and RF Connectors DC Power RF Input RF Output...

Страница 16: ...Manual 7 2 4 Rear Views Figure 5 Paragon III rear view Figure 6 Backplane Power Supply connection to Power Amplifier 10 amp fuse Paragon III minus Power Amp 2 x 15 amp fuses in parallel for Power Amp...

Страница 17: ...nstall the grounding lead s lug over the binding post and firmly hand tighten the binding nut If a DC rail 0V is installed as part of the system the grounding leads may alternatively be fit ted to the...

Страница 18: ...Type A B C Maxi Fuse 1 15 29 21 1 35 34 29 35 8 89 Fuse F1 F2 F3 Values 10A 15A 15A Always replace the two 15A fuses as a pair Figure 7 Maxi Fuse 2 6 Power Amplifier Although the T809 10 is a high eff...

Страница 19: ...Common pliers are NOT acceptable 2 8 Completing the physical Installation Paragon III products are factory configured to user s requirements and are shipped ready to run After new installations Re che...

Страница 20: ...ked LOCK LED Red PLL not locked Green RF carrier signal on audio channel 1 is above manually adjusted mute threshold 1 LED Off RF carrier signal on audio channel 1 is below manually adjusted mute thre...

Страница 21: ...communication error Microphone Socket not used F Figure 9 5W Exciter module 3 1 3 70W Power Amplifier The power amplifier is maintenance free only LED indications and a front panel adjustment are prov...

Страница 22: ...oggles AirLink down mode after 4 seconds 2x DE 9 RS 232 ports for setup and user data 1X rocker switch positions PF 1 and 2 to select various test modes 2x Ethernet ports for setup and user data 2x Et...

Страница 23: ...current limiting Reset auto recovery Over voltage 18 to 21 VDC shutdown Reset Power OFF and ON Over temperature shutdown of output voltage auto recovery with temperature reduction temperature sensed...

Страница 24: ...output voltage turn the trim pot counterclockwise If the output voltage is increased on a power supply operating at or close to full load the power supply loading must be reduced accordingly or the mo...

Страница 25: ...for logging and later analysis Transmission of online diagnostics may be enabled or dis abled at any station or stations without affecting their ability to communicate with other stations Additional i...

Страница 26: ...on parameters and operating firmware can be updated remotely even over the RF network itself using the standard FTP protocol 4 2 Default IP Settings Paragon III radio modem supports the Router IP Forw...

Страница 27: ...oth Base and Mobile s Figure 16 IP Network Settings in Router Mode with Router Paragon III Base DATA Eth1 IP 192 168 202 1 MASK 255 255 255 0 RF IP 10 0 0 1 MASK 255 0 0 0 Mobile DHCP Server RF IP 10...

Страница 28: ...eway blank 6 Click the OK button Note On computers running Windows 9X reboot to complete the connection process 4 5 Login Screen On the Address line of the Internet browser of your choice type the fac...

Страница 29: ...r Encryption Key 2 Click Apply Parameters 3 Click Save Parameters 4 7 Interface The Paragon III user interface Figure 18 provides easy access to the various menus used to configure and view your netwo...

Страница 30: ...xes or radio buttons only in the opened window If needed go to other Submenu s and make more entries Click Apply Parameters before leaving each window When finished click a Save Parameters button in a...

Страница 31: ...ach individual unit Network Mask Set to valid IP netmask for each individual unit may be same or differ ent depending on customer s IP network topology IP Default Gateway Set to valid Default Gateway...

Страница 32: ...hernet Interface 1 IP MTU Default 1500 Range 576 to 1500 bytes Factory MAC address Ethernet Interface 1 factory Dataradio MAC address in HEX format DHCP Server Disabled Enabled Default Ethernet Interf...

Страница 33: ...2 10 Security Table 13 Security Item Description User ID Enter a string of any letters or numbers of at least 1 and not exceeding 15 characters Old Password For initial installation enter a string of...

Страница 34: ...ckets TCP Stats Total TX packets Total RX packets Eth 1 ARP Stats Total TX packets 4 7 2 13 RF Test Table 16 RF Test Item Description Ping Test Tones 4 7 2 14 FTP Transfer Table 17 FTP Transfer Item D...

Страница 35: ...roneous indications from service monitors that have not adequately warmed up This is particularly likely when field service is done during winter months 5 2 Recommended Checks A After an installation...

Страница 36: ...ress CDip Get button as per CDip Help content 3 Power Amplifier Output Power Press TXON Unmod 70 watts 10 Service monitor set to read power or 100W in line watt meter installed as close as possible to...

Страница 37: ...er power up then keeps flashing in tune to the cycle marker RX and STATUS LEDs remain OFF 2 Connect and save unit config Press CDip Get button as per CDip Help content 3 Transmitter Output Power Press...

Страница 38: ...an 108 dBm including cable loss Typically 109 to 110 dBm Backplane corre sponding to the re ceiver being verified J1 RX1 or J5 RX2 Pin 6 Service monitor IFR set to SINAD IFR IF filter set to MID posit...

Страница 39: ...ddress range is 1 126 As an Alpha Mapped Nibble AMN address consisting of upper case letters in the range A P The valid address range is A to GN The base address is usually 1 The program may display o...

Страница 40: ...d prompt displays the intermediate routers be tween local host to the ww yahoo com site 5 4 2 Configuration Information WINIPCFG WIN95 98 IPCONFIG WIN2K or IFCONFIG UNIX Ipconfig is a DOS utility whic...

Страница 41: ...lays help route print displays the routing table 5 4 3 Statistics Information NETSTAT WINS UNIX The netstat command symbolically displays the contents of various network related data struc tures i e I...

Страница 42: ...an underlined letter on the menu command On a drop down menu press only the hotkey without pressing the Alt key Use the Tab key to cycle available fields and the Enter key to validate entries E g Pre...

Страница 43: ...120 20191 100a Paragon III User Manual 34 Figure 21 Exciter System Infomation Sample Figure 22 Exciter Channel Information Sample...

Страница 44: ...binary count is inactive The various DIP switch combinations of ON or OFF make up a binary total which identifies the channel num ber To select a channel set the appropriate DIP switch or switches to...

Страница 45: ...wrench RF tuning trimming tools Extender Rail Kit for Series II chassis T800 13 0000 1x 6 coax cable N M to BNC M comes with the radio to connect the exciter to the PA 6 2 2 Transmitter Module T881 1...

Страница 46: ...IFR RX frequency to match the main radio TX frequency IF Filter set to 30KHz Zoom the RF Error window select 10Khz range 2 Key the transmitter by pressing the front panel TX Key button and measure the...

Страница 47: ...120 20191 100a Paragon III User Manual 38 Figure 24 T881 0200 Transmitter Tuning Controls location...

Страница 48: ...ption 120 VAC TBD Channel spacing 50 kHz Operating Temperature Range 30 C to 60 C deleted power supply catalog number with 0 in second to last digit 10 C to 60 C with standard Dual Power Supply assy c...

Страница 49: ...djustment 3dB Nominal Spurious Harmonics 70 dBc input output Impedance 50 ohms Load VSWR Tolerance 20 1 Max 30 seconds input output connectors Type N female Operating Temperature Range 30 degrees C to...

Отзывы: