
Fuse
7.5 A
Sealed battery
Using the sealed battery for the first time
INSTRUCTIONS FOR REFRESHING THE STOCK CHARGE OF AN OPEN CIRCUIT
1) Voltage check
Before installing the battery on the vehicle, check the open circuit voltage with a normal tester.
- If the voltage exceeds 12.60 V, the battery may be installed without any renewal recharge.
- If voltage is below 12.60 V, a renewal recharge is required as explained in 2).
2) Constant voltage battery charge mode
-Constant voltage equal to 14.40÷14.70V
-Initial charge voltage equal to 0.3÷0.5 for nominal capacity
-Duration of the charge: 10 to 12 h recommended
Minimum 6 h
Maximum 24 h
3) Constant current battery charge mode
-Charge current equal to 1/10 of the nominal capacity of the battery
-Duration of the charge: 5 h
WARNING
-WHEN THE BATTERY IS REALLY FLAT (WELL BELOW 12.6V) IT MIGHT BE THAT 5 HOURS OF
RECHARGING ARE NOT ENOUGH TO ACHIEVE OPTIMAL PERFORMANCE.
IN THESE CONDITIONS IT IS HOWEVER ESSENTIAL NOT TO EXCEED EIGHT HOURS OF CON-
TINUOUS RECHARGING SO AS NOT TO DAMAGE THE BATTERY ITSELF.
Dry-charge battery
WARNING
THE BATTERY ELECTROLYTE IS POISONOUS AS IT MAY CAUSE SERIOUS BURNS. IT CON-
TAINS SULPHURIC ACID. AVOID CONTACT WITH THE EYES, THE SKIN AND CLOTHING. IF
COMING INTO CONTACT WITH EYES OR SKIN, WASH ABUNDANTLY WITH WATER FOR AP-
PROX. 15 MIN. AND SEEK IMMEDIATE MEDICAL ATTENTION.
IN THE EVENT OF ACCIDENTAL INGESTION OF THE LIQUID, IMMEDIATELY DRINK LARGE
QUANTITIES OF WATER OR MILK, MAGNESIUM MILK, BATTERED EGG OR VEGETABLE OIL.
SEEK IMMEDIATE MEDICAL ATTENTION.
THE BATTERIES PRODUCE EXPLOSIVE GAS; KEEP CLEAR OF NAKED FLAMES, SPARKS OR
CIGARETTES; VENTILATE THE AREA WHEN RECHARGING INDOORS.
ALWAYS WEAR EYE PROTECTION WHEN WORKING IN THE PROXIMITY OF BATTERIES.
KEEP OUT OF REACH OF CHILDREN
Use of dry-cell batteries :
1. Having removed the short, closed tube and removed the caps, put into the elements sulphuric
acid of the type for specific weight 1.26 accumulators corresponding to 30° Bé at a temperature
of no less than 15°, until you reach the upper level.
Runner RST 50 SP
Electrical system
ELE SYS - 57
Содержание Runner RST 50 SP
Страница 1: ...SERVICE STATION MANUAL 639189 Runner RST 50 SP ...
Страница 4: ......
Страница 6: ...INDEX OF TOPICS CHARACTERISTICS CHAR ...
Страница 17: ...INDEX OF TOPICS TOOLING TOOL ...
Страница 26: ...INDEX OF TOPICS MAINTENANCE MAIN ...
Страница 37: ...INDEX OF TOPICS TROUBLESHOOTING TROUBL ...
Страница 43: ...INDEX OF TOPICS ELECTRICAL SYSTEM ELE SYS ...
Страница 60: ...INDEX OF TOPICS ENGINE FROM VEHICLE ENG VE ...
Страница 66: ...INDEX OF TOPICS ENGINE ENG ...
Страница 98: ...INDEX OF TOPICS SUSPENSIONS SUSP ...
Страница 109: ...INDEX OF TOPICS BRAKING SYSTEM BRAK SYS ...
Страница 117: ...INDEX OF TOPICS COOLING SYSTEM COOL SYS ...
Страница 123: ...Runner RST 50 SP Cooling system COOL SYS 123 ...
Страница 124: ...INDEX OF TOPICS CHASSIS CHAS ...
Страница 136: ...Chassis Runner RST 50 SP CHAS 136 ...
Страница 137: ...INDEX OF TOPICS PRE DELIVERY PRE DE ...
Страница 141: ...INDEX OF TOPICS TIME TIME ...
Страница 143: ...Crankcase CRANKCASE Code Action Duration 1 001133 Engine crankcase Replacement Runner RST 50 SP Time TIME 143 ...