1 .6 .2 .7 Shorter & Different Ticket printouts.
During digital setup of the GS8920 Ticket Printer a wide range of printed format options is made
available.
The lines of printing on the ticket can be left or right justified. In addition, the entire printing on the
ticket can be left or right justified so that a large right hand margin is possible. Certain information
which appears in the earlier examples can be removed. If all of the weights are not required then only
the gross or only the net weight may be printed. The GS8920 can even be setup so as NOT to print a
ticket at all. The following examples are modifications to the earlier examples showing the result of
different setup selections.
GS8920 Intelligent Ticket Printer.
1-36
Ac[20]+
10-02-90 12:26PM
003.876t G
002.700t T
001.176t N
There is no heading as the ticket heading facility was not set up
during installation.
There are no temporary ID numbers as none was entered prior
to printing the ticket.
The permanant ID number does not appear as it was set to zero
(000000) during normal operation of the GS8920 Printer.
The accumulator’s material code does not appear as it was set
to zero (000000) during normal operation of the GS8920
Printer.
The device number of the weight indicator does not appear as it
was set to zero on installation of the indicator.
The 12 digit rolling print counter does not appear as it was
disabled during digital setup of the GS8920 Printer.
Leading zero suppression is not active and tonnes have been
selected as the unit of measure.
Ac[20]+
003.876t G
The time and date do not appear as the indicator to which the
GS8920 Printer is connected does not have a time and date
facility.
Gross weight printout only was selected during digital setup of
the GS8920 Printer. Net weight only could also have been
selected.
ID No000055
tare register tr[06]
Ac[03]+ Code 330005
24-02-90 16:36 dn39
rpc000000456790
07460.0kg G
-03450.2kg T
04009.8kg N
Right justified printout instead of left justified printout. This
selection is made during digital setup of the GS8920 Printer.
Positive tare weights can be printed as positive without a sign
or can be designated as negative and printed with a minus
sign. This requirement is necessary in order to satisfy certain
weighing authorities’ requirements and is established on
digital setup of the GS8920 Printer
Leading zero blanking is not used..