OP ER A TION
M
Operates with ALL serial output equipped
GS
digital weight indicators as well as other
selected digital weight indicators.
M
Item entry of quantity and price for piece computing and counting. (requires Option
BR2
)
M
Uses either the time and date from the
GS
digital weight indicator or the time and date from
the optional calendar/clock fitted within the GS8920.( Option
BR2
Calendar/Clock)
M
Completely Automatic RS-232C or 20mA Current Loop input selection as well as Baud rate
and parity bit setting at power up. No need to EVER set the baud rate or parity setting.
M
Full Digital Setup using the front panel keyboard. Access to the inside of the GS8920 is NOT
required.
M
Very extensive user configurable print format provides over
9,000
possible printed
configurations for the weight printout.
M
Multiple copies available on CARD stock via the “COPY” print feature.(Up to 4 additional
copies are available. )
M
Fully Automatic ticket positioning to wide range of settable starting positions.
M
Fully Automatic ticket ejection settable to front, rear or off.
M
Standard ticket sensors for top of form and bottom of form.
M
Automatic ticket request message if ticket not inserted.
M
Keyboard Entry/Store and Recall up to 50 tare values which are checked for legal range by
the GS8920.
M
Automatic tare allocation for Weigh In and Weigh Out operation.
M
Add up to 30 weights to form one weighment or just 2 weights for end to end weighing.
M
Interlock access to the Totals and Security Registers and Alpha names.
M
Interlock access to the GS8920’s set up.
M
Add to or Subtract from any one of 50 Accumulators.
M
Print/Accumulate only Gross or only Net weight or Gross, Tare and Net weight.
M
Selectable Rolling Print Counter on all tickets.
M
Selectable Left or Right Line Justified Printing.
M
Selectable line indent of up to 11 character spaces.
M
Selectable page justification via normal or inverted printing for all possible page justifications
against left or right side of page.
M
Selectable leading zero suppression. Proper zero rules automatically apply. The GS8920 prints
“0.0" for zero with decimal places and ”00" for zero with count by 10, 20 or 50.
M
Selectable Print test at power up.
M
No data loss when out of paper.
M
Adjustable normal size printing from 1.6mm high to 3.6mm high by 1.6mm wide.
M
Adjustable enhanced printing, double high 3.2mm to 7.2mm high by 1.6mm wide, double
wide 1.6mm to 3.6mm high by 3.2mm wide and double high/double wide 3.2mm to 7.2mm
high by 3.2mm wide.
M
Selectable print enhancement; choose weight, ID Number or Weight and ID Number.
M
Selectable interline spacing from 0.7mm up to 7.9mm for normal high and 1.4mm up to
15.8mm for double high printing.
M
Automatic Page Numbering for printed lists of the Security Register and Accumulators.
M
Following an Accumulate command the GS8920 can be configured to either :-
1
. Abort on Motion.
2
. Await a still condition and then accumulate a weight.
3
. If still to first await a motion condition then a still condition before accumulating a weight.
FEAT-3