CHAPTER 5: SETTINGS
469 MOTOR MANAGEMENT RELAY – INSTRUCTION MANUAL
5–77
5.9.6
Open RTD Sensor
PATH: SETTINGS
S8 RTD TEMPERATURE
OPEN RTD SENSOR
The 469 has an Open RTD Sensor alarm. This alarm will look at all RTDs that have either an
alarm or trip programmed and determine if an RTD connection has been broken. Any RTDs
that do not have a trip or alarm associated with them will be ignored for this feature. When
a broken sensor is detected, the assigned output relay will operate and a message will
appear on the display identifying the RTD that is broken. It is recommended that if this
feature is used, the alarm be programmed as latched so that intermittent RTDs are
detected and corrective action may be taken.
5.9.7
RTD Short/Low Temp
PATH: SETTINGS
S8 RTD TEMPERATURE
RTD SHORT/LOW TEMP
The 469 has an RTD Short/Low Temperature alarm. This alarm will look at all RTDs that
have either an alarm or trip programmed and determine if an RTD has either a short or a
very low temperature (less than –50°C). Any RTDs that do not have a trip or alarm
associated with them will be ignored for this feature. When a short/low temperature is
detected, the assigned output relay will operate and a message will appear on the display
identifying the RTD that caused the alarm. It is recommended that if this feature is used,
the alarm be programmed as latched so that intermittent RTDs are detected and
corrective action may be taken.
OPEN
[
]
RTD SENSOR
OPEN RTD SENSOR
ALARM: Off
Range: Off, Latched, Unlatched
MESSAGE
ASSIGN ALARM RELAYS:
Alarm
Range: Alarm, Alarm & Auxiliary2,
Alarm & Aux2 & Aux3, Alarm &
Auxiliary3, Auxiliary2, Aux2 &
Aux3, Auxiliary3, None
MESSAGE
OPEN RTD SENSOR
ALARM EVENTS: Off
Range: On, Off
RTD
[
]
SHORT/LOW TEMP
RTD SHORT/LOW TEMP
ALARM: Off
Range: Off, Latched, Unlatched
MESSAGE
ASSIGN ALARM RELAYS:
Alarm
Range: Alarm, Alarm & Auxiliary2,
Alarm & Aux2 & Aux3, Alarm &
Auxiliary3, Auxiliary2, Aux2 &
Aux3, Auxiliary3, None
MESSAGE
RTD SHORT/LOW TEMP
ALARM EVENTS: Off
Range: On, Off
Содержание Masoneilan 469 Series
Страница 4: ......
Страница 91: ...CHAPTER 3 INSTALLATION 469 MOTOR MANAGEMENT RELAY INSTRUCTION MANUAL 3 27 3 2 14 2 Speed Motor Wiring ...
Страница 92: ...3 28 469 MOTOR MANAGEMENT RELAY INSTRUCTION MANUAL CHAPTER 3 INSTALLATION ...
Страница 256: ...5 112 469 MOTOR MANAGEMENT RELAY INSTRUCTION MANUAL CHAPTER 5 SETTINGS ...
Страница 298: ...6 42 469 MOTOR MANAGEMENT RELAY INSTRUCTION MANUAL CHAPTER 6 ACTUAL VALUES ...
Страница 300: ...7 2 469 MOTOR MANAGEMENT RELAY INSTRUCTION MANUAL CHAPTER 7 TESTING FIGURE 7 1 Secondary Injection Test Setup ...
Страница 319: ...CHAPTER 8 APPENDIX 469 MOTOR MANAGEMENT RELAY INSTRUCTION MANUAL 8 7 HGF5C 808841A1 HGF8 808842A1 ...
Страница 321: ...CHAPTER 8 APPENDIX 469 MOTOR MANAGEMENT RELAY INSTRUCTION MANUAL 8 9 808712A1 CDR ...
Страница 330: ...8 18 469 MOTOR MANAGEMENT RELAY INSTRUCTION MANUAL CHAPTER 8 APPENDIX ...