CHAPTER 4: INTERFACES
469 MOTOR MANAGEMENT RELAY – INSTRUCTION MANUAL
4–7
To enter a given Setpoints page, press the
MESSAGE
or
ENTER
key.
Press the
MESSAGE
or
MESSAGE
keys to scroll through sub-
page headers until the required message is reached.
The end of a page is indicated by the message
END OF PAGE
. The
beginning of a page is indicated by
TOP OF PAGE
.
Each page is broken further into subgroups.
Press
MESSAGE
or
MESSAGE
to cycle through subgroups until
the desired subgroup appears on the screen.
Press the
MESSAGE
or
ENTER
key to enter a subgroup.
Each sub-group has one or more associated settings messages.
Press the
MESSAGE
or
ENTER
key to enter the setting message.
Press the
MESSAGE
or
MESSAGE
keys to scroll through more
settings messages, if applicable.
The majority of settings are changed by pressing the
VALUE
keys until the desired value
appears, and then pressing
ENTER
. Numeric settings may also be entered through the
numeric keys (including decimals). If the entered settings is out of range, the original
settings value reappears. If the entered settings is out of step, an adjusted value will be
stored (e.g. 101 for a settings that steps 95, 100, 105 is stored as 100). If a mistake is made
entering the new value, pressing
ESCAPE
returns the settings to its original value. Text
editing is a special case described in detail in
Each time a new settings is successfully stored, a message will flash on the display stating
NEW SETPOINT HAS BEEN STORED
.
Press the 4, 6, 9 keys, then press
ENTER
. The following flash message
is displayed:
and the display returns to:
1. Press
ESCAPE
or
MESSAGE
to exit the subgroup. Pressing
ESCAPE
or
MESSAGE
numerous times will always return the cursor to the top of the
page.
4.1.7
Diagnostic Messages
Diagnostic messages are automatically displayed for any active conditions in the relay
such as trips, alarms, or asserted logic inputs. These messages provide a summary of the
present state of the relay. The Message LED flashes when there are diagnostic messages
available; press the
MENU
key until the relay displays
TARGET MESSAGES
, then press the
PASSCODE
[
]
ENTER PASSCODE FOR
ACCESS:
NEW SETPOINT HAS
BEEN STORED
SETPOINT ACCESS:
Permitted
Содержание Masoneilan 469 Series
Страница 4: ......
Страница 91: ...CHAPTER 3 INSTALLATION 469 MOTOR MANAGEMENT RELAY INSTRUCTION MANUAL 3 27 3 2 14 2 Speed Motor Wiring ...
Страница 92: ...3 28 469 MOTOR MANAGEMENT RELAY INSTRUCTION MANUAL CHAPTER 3 INSTALLATION ...
Страница 256: ...5 112 469 MOTOR MANAGEMENT RELAY INSTRUCTION MANUAL CHAPTER 5 SETTINGS ...
Страница 298: ...6 42 469 MOTOR MANAGEMENT RELAY INSTRUCTION MANUAL CHAPTER 6 ACTUAL VALUES ...
Страница 300: ...7 2 469 MOTOR MANAGEMENT RELAY INSTRUCTION MANUAL CHAPTER 7 TESTING FIGURE 7 1 Secondary Injection Test Setup ...
Страница 319: ...CHAPTER 8 APPENDIX 469 MOTOR MANAGEMENT RELAY INSTRUCTION MANUAL 8 7 HGF5C 808841A1 HGF8 808842A1 ...
Страница 321: ...CHAPTER 8 APPENDIX 469 MOTOR MANAGEMENT RELAY INSTRUCTION MANUAL 8 9 808712A1 CDR ...
Страница 330: ...8 18 469 MOTOR MANAGEMENT RELAY INSTRUCTION MANUAL CHAPTER 8 APPENDIX ...