9-1
9. List of Peripheral Equipment and Options
The table below lists the main peripheral equipment and options that may be connected to the AF-300 Mini. Use
them in accordance with your system requirements.
REFERENCE: For details, refer to the AF-300 Mini User’s Manual, Chapter 6 “Selecting Peripheral Equipment.”
Name of
peripheral
equipment
Function and application
Main peripheral equipment
Molded case
circuit breaker
(MCCB)
Molded Case Circuit Breakers (MCCBs) are designed to protect the power circuits between the power
distribution panel and the drive’s main terminals (L1/R, L2/S and L3/T for 3-phase, or L1/L and L2/N for
1-phase power source) from overload or short-circuit. This in turn prevents secondary damage caused by the
drive malfunctioning. Use the MCCBs with recommended rated currents listed in the table below.
Applicable Motor
Rating (hp)
Drive Hp
Recommended rated current (A)
of MCCB
w/DC Reactor
w/o DC
Reactor
3-phase 230 V
1/8
1/8
5
5
1/4
1/4
1/2
1/2
1
1
10
2
2
10
15
3
3
20
5
5
20
30
3-phase 460 V
1/2
1/2
5
5
1
1
2
2
10
3
3
15
5
5
10
20
1-phase 230 V
1/8
1/8
5
5
1/4
1/4
1/2
1/2
10
1
1
10
15
2
2
15
20
3
3
20
20
1-phase 115 V
1/8
1/8
5
5
1/4
1/4
5
10
1/2
1/2
10
15
1
1
15
20
StockCheck.com
Содержание Fuji Electric MICRO-SAVER AF-300
Страница 1: ...GEH 6647 AF 300 Mini Startup Guide S t o c k C h e c k c o m ...
Страница 20: ...1 4 Notes S t o c k C h e c k c o m ...
Страница 36: ...2 16 Notes S t o c k C h e c k c o m ...
Страница 56: ...3 20 Notes S t o c k C h e c k c o m ...
Страница 102: ...7 8 Notes S t o c k C h e c k c o m ...
Страница 112: ...8 10 8 4 External Dimensions See dimensions table on next page S t o c k C h e c k c o m ...
Страница 118: ...8 16 Notes S t o c k C h e c k c o m ...
Страница 126: ...10 4 Notes S t o c k C h e c k c o m ...